57
DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERMI-
NATOR
DTMF
ACK
DEFAULT
35#
Bi
Silent Mode
0 = Silent mode On, 1 = Silent mode Off
#
Bi
Silent mode Off
37#
Bi
AC fault report, 0 = Off, 1 = On
#
Bi
On
38#
Bi
Follow-On & Call Back Function, 0 = Follow-On, 1=
Call-Back, 2= Follow-On & Call-Back
#
Bi
Follow-On
39#
Bi
Dialling Mode
0 = Tone, 1 = Pulse
#
Bi
Tone
40#
Bi
To Set Access Code
#
Bi
8744
41#
Bi
Auto answer for Remote programming,
00 = None, 01 - 32 = Auto answer 1 - 32 rings
#
Bi
20 rings
42#
Bi
Guard time delay
00 = Instant Reporting
99 = 99 seconds
#
Bi
Instant Reporting
43#
Bi
Test call, 0 = OFF, 1 = 1 Day, 2 = 2 Days,
3 = 3 Days, 4 = 4 Days. 5 = 5 Days,
6 = 6 Days, 7 = 7 Days, 8 = 30 days
#
Bi
No Test Call
44#
Bi
Mobility time
0= Disable, 1=12 Hour, 2=24 Hour
#
Bi
Mobility time
disable
45#
Bi
Follow-On Choice, 0 = Wait command,
1 = Listen, 2 = Two way voice communication
#
Bi
Two-way voice
communication
46#
Bi
Follow-On mode & Two-Way Period,
01=1 min, 02=2mins, 03=3mins, 04=4mins,
05=5mins, 06=6mins, 07=7mins, 08=8mins,
09=9mins, 10=10mins.
#
Bi
2 minutes
47#
Bi
Off-set time, 1=1 hour, 2=2 hours, 3=3 hours,
4=4 hours, 5=8hours, 6=12 hours
#
Bi
1 Hour
49#
Bi
Supervision
0 = disable, 1 = 4 days, 2 = 5 days, 3 = 6 days,
4 = 7 days, 5 = 8 days, 6 = 9 days, 7 = 10 days
#
Bi
Disable
53#
Bi
Voice prompt language,
0=English, 1=Spanish, 2=Russian, 3= Arabic
#
Bi
0
55#
Bi
High Temperature Reporting threshold
000 = 0 °C, 001-999=0.1-99.9 °C
#
Bi
350
(35.0 °C)
56#
Bi
Low Temperature Reporting threshold
000 = 0 °C, 001-999=0.1-99.9 °C
#
Bi
080
(8 °C)
57#
Bi
CO2 Alarm Reporting Threshold
0 - 9999ppm
#
Bi
800ppm
61#
Bi
Telephone number for medical alarm report
#
Bi
1,2
62#
Bi
Telephone number for fire alarm report
#
Bi
3,4
63#
Bi
Telephone number for status report
#
Bi
5,6
66#
Bi
Guard time delay for Fall Sensor, 00 = Instant
reporting
; … 99 = 99 seconds
#
Bi
10 sec
67#
Bi
Help Arrived Timer
01-15 = 1-15 minutes
#
Bi
15 minutes
75#
Bi
Help Not Arrived Call
#
Bi
No number
76#
Bi
Call progress tone, 0 = Off, 1 = On
#
Bi
Off
77#
Bi
Send No-Pendant Learned-in report
0=Disable, 1=Enable
Enable
80#
Bi
Remove all device
---
---
---
81#
Bi
Remove Zone One Device
---
---
---