14
Command 42
Guard Time Delay
This command is designed for any
compatible sensor, except Fall Sensor
(fall detection).
SUPER 32-DT35A can be programmed to
delay alarm reporting from (
00
) (instant
reporting) to (
99
) seconds.
During this time period, a continuous series
of beeps will be emitted to alert user.
If a false alarm is triggered, it can be
cancelled within the Guard Time Delay.
Function
Selection
Result
(00)
INSTANT REPORTING
(01) - (99)
DELAY
Factory Default is (
00
),
Instant Reporting
.
<NOTE>
The Emergency alarm cannot be
cancelled after the Guard Time is
elapsed.
If an emergency alarm is triggered by
pressing the Active Button on Fall
sensor, the guard time delay time is
determined by
Command 42
, instead
of
Command 66
.
The Guard Time Delay for Fall Sensor
fall detection is set by
Command 66
.
Command 43
Periodic Test Call
SUPER 32-DT35A can be programmed to
make test calls periodically from (00) (no
test call) to every (1) - (7) or 30 days:
Function Selection
Result
(0)
OFF
(1) - (7)
1 - 7 DAYS
(8)
30 DAYS
Factory Default is set as (
0
),
OFF.
<NOTE>
Whenever programming mode is
accessed, SUPER 32-DT35A will
reset the Periodic Test Call timer.
Command 44
Mobility Timer
This function monitors user movement around
the premises and sends an inactivity report to
the Monitoring Center if the user fails to reset
the inactivity timer.
This will disable or enable the Inactivity
Timer with selectable count down periods.
Options are:
Function
Selection
Result
(0)
DISABLE
(1)
12HR
(2)
24HR
Factory Default is set as (
0
),
DISABLE
.
<NOTE>
The Mobility Timer counting down can be
reset by:
1.
Pressing the
RESET
button on
SUPER 32-DT35A, or,
2.
Movement detected by PIR Detector
When Mobility Timer expires and no reset
signal is received, SUPER 32-DT35A starts
to emit one long beep every 5 minutes to
alert the user. After 30 minutes, if reset
signal is not received, a mobility alarm
reporting will be made.
The reporting method for mobility alarm is
the same as the emergency alarm. The
report will be sent based on your reporting
methods without guard time waiting.
When (
0
) is selected, no code is sent to
Monitoring Centers.
When SUPER 32-DT35A is in idle mode,
pressing and holding the learn button for
16 seconds (until you hear a long beep)
will suspend the Mobility Timer. Pressing
the learn button once will resume Mobility
Timer.