15
Command 45
Follow-On Mode Choice
This Command is only available for Digital
reporting with Command #38
set as (
0
) or
(
2
).
It is used to select the Follow-On Choice
for SUPER 32-DT35A after it has made a
report to the Monitoring Center.
After reporting, SUPER 32-DT35A can
wait for further commands, or enter a Two-
Way Full Duplex Communication, or
Listen-In Half Duplex Communication
immediately according to the setting under
this command:
Function
Selection
Result
(0)
WAIT
COMMAND
(1)
LISTEN
(2)
TWO WAY
Factory Default is
set
as (
2
)
, TWO WAY
.
<NOTE>
When (
0
)
is selected, after reporting the
Contact ID Code, SUPER 32-DT35A will
wait for 1-10-min, set by Cammand 46
,
and
then follows the DTMF commands that are
received from the Central Monitoirng Station
for action.
If no command is received after the waiting
period, the system will automatically return
to Idle mode.
When (
1
)
is selected, after SUPER 32-
DT35A has made a report to the Monitoring
Center, it will automatically enter
Listen-In
Half Duplex
for 1-10 minutes (set by
Command 46) allowing the Monitoring
Center Personnel to listen in to what is
happening on the other side.
When (
2
) is selected, after reporting, the
SUPER 32-DT35A will immediately enter a
Two-way Full-duplex Communication
mode for 1-10 minutes (set by Command
46), that gives the user the ability to speak
directly
with
the
Monitoring
Center
Personnel.
If either Scancom or Tunstall reporting
format is selected, SUPER 32-DT35A will
ignore Command #45 selections. It will
always open a Two-way voice for Follow-On
choice.
Command 46
Follow-On Mode & Two way Period
This command is used to program the
allowable time duration for Follow-On
mode choice (Commend #45) & Two-way
voice communication period (Speech
mode or Dial Call Reporting). It can be set
from (
01
) (1 minute) - (
30
) (30 minutes).
Function Selection
Result
(01)
1 minute
(02)
2 minutes
(03)-(30)
3-30 minutes
The allowable time duration for
Dial Call
Reporting
is 1-30 minute(s); Factory
default is set as (
15
) 15 minutes.
The allowable time duration for either
Wait
Command
,
Two-way
,
Listen-In Only
or
Two-way
voice
comminucation
in
Speech mode
is 1-30 minute(s). During
the period, SUPER 32-DT35A will emit two
beeps via the telephone handset to alert
the call recipient the remaining time of 20 &
10 secs. Pressing assigned DTMF key can
extend another 1-30 minute(s).
Command 47
Off-Set time
After the Control Panel‘s power is
supplied, the time of the Check-in Report
starts calculating.
According to the setting of Off-Set time,
the Control Panel will send Check-in
Report once, and then send report
according to the setting of Command 43
-
Periodic Test call.
Function Selection
Result
(1)
1 Hour
(2)
2 Hour
(3)
3 Hour
(4)
4 Hour
(5)
8 Hour
(6)
12Hour