31
44# Mobility Timer:
-
This function monitors user movement around the premises and sends an inactivity report to
the Monitoring Center if the user fails to reset the inactivity timer.
-
Inactivity Timer can be selected as 12HR, 24HR count down periods, or it can be disabled.
-
The Mobility Timer counting down can be reset by either pressing the RESET button on the
Panel, or movement detected by PIR Detector.
45# Follow-On Mode Choice:
-
This function is only available for Digital reporting with either Follow-On or Follow-On & Call-
Back is enabled. It is used to select the Follow-On Choice for the Panel after it has made a
report to the Monitoring Center.
-
When
“Wait Command”
is selected, after reporting the Contact ID Code, the Panel will wait
for 1-30 min(s), set by Command 46, and then follows the DTMF commands that are
received from the Central Monitoring Station for action. If no command is received after the
waiting period, the system will automatically return to Idle mode.
-
When
“Listen”
is selected, after the Panel has made a report to the Monitoring Center, it will
automatically enter
Listen-In Half Duplex
for 1-30 minute(s) (set by Command 46) allowing
the Monitoring Center Personnel to listen in to what is happening on the other side.
-
When
“Two way voice communication”
is selected, after reporting, the Panel will
immediately enter a Two-way Full-duplex Communication mode for 1-30 minute(s) (set by
Command 46), that gives the user the ability to speak directly with the Monitoring Center
Personnel.
-
If either Scancom or Tunstall reporting format is selected, the Panel will ignore this field’s
selection. It will always open a Two-way voice for Follow-On choice.
46# Follow-On Mode & Two way Period:
-
This is used to program the allowable time duration for Follow-On mode choice (Commend
#45) & Two-way voice communication period (Speech mode). It can be set from 1 to 30
minutes.
47# Off-Set Time:
-
This is to set the time delay before the first
Periodic Test Call
is made. After power is
supplied or re-supplied to the Control Panel, the first auto check-in report will be made
according to Offset Period setting. This is used to test whether the CMS is able to receive
the report from the Panel accurately.
-
After this test report is sent, the Control Panel will then send reports at regular interval based
on the setting of the
Periodic Test Call
.
49# Supervision:
-
When enabled, the Panel will be able to receive the check-in signals from Wrist Pendants
(WTR-) to indicate their proper functioning. When the selected supervisory timer expires
and no supervision signal is received from WTR-, the supervisory alarm reporting will be
made.
The reporting method for supervisory alarm is the same as the emergency alarm. The
report will be sent based on your reporting methods without guard time waiting.
-
When
disabled,
no code is sent to Monitoring Center.
53# Voice Prompt Language:
-
Select the voice prompt language for the Panel. Available options include English, Spanish,
Russian, and Arabic.