Climax SUPER 32-DT35A Скачать руководство пользователя страница 53

       

 

50 

 

When  Pendant  2  is  pressed  or 
triggered. 

 

515555518  –  Pendant  1  Emergency 
(Low Battery) 

 

When  Pendant  1  is  pressed  or 
triggered under Low Battery status. 

 

555155518  –  Pendant  2  Emergency 
(Low Battery) 

 

When  Pendant  2  is  pressed  or 
triggered under Low Battery status. 

 

551555517 – Mobility 

 

When  SUPER  32-DT35A  makes 
Mobility Timer Expired reporting.  

 

555556558 - Panel Low battery 

 

When SUPER 32-DT35A is under Low 
Battery status, the Green LED flashes 
every  2  sec  with  2  short  beeps  every 
hour. 

 

555551557 - AC Failure 

 

When  the  AC  power  fails  for  more 
than  10  sec,  the  Green  LED  flashes 
every sec with a beep every 30 sec. 

 

555553557  -  AC  Failure  Restore  /  Panel 
Low Battery restore 

 

When  the  AC  power  failure  status  is 
restored. . 

 

When the Panel Low Battery status is 
restored 

 

515555559  -  Global  test  /  WTR 
Supervision Failure 

 

When  the  SUPER  32-DT35A  reports 
Global Test to monitoring Center. 

 

When  SUPER  32-DT35A  is  unable  to 
receive the signal transmitted from the 
Wrist 

Transmitter 

Emergency 

Pendant (WTR) for a pre-set period by 
Command #49. 

 

555555559  -  Periodic  test  report  /  Help 
Arrived 

 

When  SUPER  32-DT35A  reports 
Periodic test call to Monitoring Center. 

 

When  SUPER  32-DT35A makes  Help 
Arrived reporting. 

 

535555557  -  WTR  Supervision  Failure 
Restore / WS Emergency Restore 

 

When  the  WTR  supervision  failure 
status is restored.

 

 

When  WS  emergency  status  is 
restored.

 

 

555555558 - Device Low Battery 

 

When  devices  are  under  Low  Battery 
Status, the Green LED flashes every 2 
sec with 3 beeps every hour.

 

 

555555557 - Device Low Battery Restore 

 

When  the  device  Low  Battery  status, 
is restored.

 

 

155555517 - SD or CO emergency 

 

When  the  Smoke  Detector  (SD)  or 
Carbon  Monoxide  Detector  (CO)  is 
triggered. 

 

When  Smoke  Detector  (SD)  button  is 
pressed. 

 

355555557  -  SD  or  CO  emergency 
restore 

 

When  the  Smoke  Detector  (SD)  or 
Carbon  Monoxide  Detector  (CO) 
emergency status is restored. 

7.4. VRI Event code

 

 

00 – Medical Help Needed/ Mobility 

 

When  the  HELP  Panel  button  is 

pressed 

 

When  the  SUPER  32-DT35A  makes 

Mobility Timer Expired reporting. 

 

11  –  Fire  /  Smoke  /  Gas  Detected /  CO 
Action/ Water Leakage Help Needed 

 

When  detecting  Fire,  Smoke,  Gas,           

Carbon  Monoxide  or  Water  leakage, 
SD, CO and WS will be triggered.  

 

When the SD button is pressed. 

 

22 – AC Failure 

 

When  the  AC  power  fails  for  more 

than  10  sec,  the  Green  LED  flashes 
every  2  sec  with  a  beep  every  30 
secs. 

 

33 – AC Failure Restore 

 

When the AC power is restored to the 

SUPER 32-DT35A. 

 

44 – Low Battery (

WTR/ Fall Sensor

 

When  the  Wrist  Transmitter  / 

Emergency  Pendant  (WTR),  or  Fall 
Sensor  is  under  Low  Battery  status, 
the  Green  LED  flashes  every  2  secs 
with 3 beeps every hour.

 

Содержание SUPER 32-DT35A

Страница 1: ...Super 32 DT35A User Manual...

Страница 2: ..._____________________ 6 5 1 Local Programming Mode under Two way communication ________________________ 6 5 2 Remote Programming Mode _____________________________________________________ 6 5 2 1 Auto...

Страница 3: ...est Call ______________________________________________________________________ 47 6 6 Factory Reset__________________________________________________________________ 47 6 7 Enable Disable System Repo...

Страница 4: ...distorted by the Internet phone connection 1 2 What s in the Box Your SUPER 32 DT35A package includes the following items Items SUPER 32 DT35A Panel A DC 12V 1A power adapter A Telephone Cord SUPER 32...

Страница 5: ...e while in two way communication 14 Learn Button Press hold for 6 sec enter Learning Mode Press hold for 16 sec disable mobility setting 2 2 The Power Supply An AC power adapter is required to connect...

Страница 6: ...located alongside other radio transmitting devices such as mobile phones cordless phone or wireless computer network Wi Fi devices Important When drilling into a wall ensure there are no hidden cable...

Страница 7: ...it receives a test code from any device Learn in Devce under Local Learning Mode 1 Press and hold the Learn Button of the SUPER 32 DT35A When pressed the SUPER 32 DT35A will emit one beep sound initia...

Страница 8: ...Release the Learn Button at the voice prompt Release the button Ready to learn sensor SUPER 32 DT35A is now in learning mode and the white backlight will start flashing quickly 3 Under learning mode...

Страница 9: ...perator should instruct the user to enter 99 followed by to exit Programming mode and slide the Local Programming Mode Slide Switch back to Normal position NOTE The user should wait for each vocal ins...

Страница 10: ...ing commands under Local Programming Mode or Remote Programming Mode Another programming option is to use the programming software Super Tool to program your SUPER 32 DT35A from your computer Please r...

Страница 11: ...led calling the SUPER 32 DT35A with the 11th Caller ID will disable the system reporting function When SUPER 32 DT35A reporting function is disabled calling the Control Panel with the 11th Caller ID w...

Страница 12: ...reporting sequence will go through the same reporting destination for 4 times until reporting to the next reporting destination for 4 times E g 1 1 1 1 2 2 2 2 3 Function Selection Result 0 Alternate...

Страница 13: ...35A will follow the report settings for the 1st 6th Tel Numbers respectively 9 Dial Call Reporting is set as factory default for SUPER 32 DT35A Dial Call Reporting is a new reporting method used for A...

Страница 14: ...ime out period for the incoming call is 30 minutes during the communication the SUPER 32 DT35A will emit two beeps via the telephone handset to alert the call recipient the remaining time of 20 10 sec...

Страница 15: ...ng beeps guard time tone key tone and ring NOTE In silent mode the speaker still functions normally for two way voice communication and voice message playback Function Selection Result 0 ON Silent 1 O...

Страница 16: ...hin 2 mins will cause SUPER 32 DT35A to automatically disconnect the call To terminate the call press DTMF 9 or RESET BUTTON on SUPER 32 DT35A If the 5 minute waiting period is up SUPER 32 DT35A will...

Страница 17: ...ng mode is accessed SUPER 32 DT35A will reset the Periodic Test Call timer Command 44 Mobility Timer This function monitors user movement around the premises and sends an inactivity report to the Moni...

Страница 18: ...for 1 10 minutes set by Command 46 that gives the user the ability to speak directly with the Monitoring Center Personnel If either Scancom or Tunstall reporting format is selected SUPER 32 DT35A will...

Страница 19: ...l be sent based on your reporting methods without guard time waiting Command 53 Voice Prompt Language This command is used to set voice prompt language 0 English 1 Spanish 2 Russian 3 Arabic Factory d...

Страница 20: ...l s 56 1st 2nd 3rd Tel s 123 1st 3rd 4th Tel s 134 1st 4th 6th Tel s 146 2nd 3rd 5th Tel s 235 2nd 4th 5th Tel s 245 2nd 5th 6th Tel s 256 1st 2nd 3rd 4th 5th 6th Tel s 123456 Alarm Status will be rep...

Страница 21: ...Enter a telephone number followed by to program the telephone number NOTE When you program the phone number entering will cause a 3 second pause is for a switchboard system extension etc The telephone...

Страница 22: ...within the signal reception range of SUPER 32 DT35A If no signal is received within 20 sec SUPER 32 DT35A will emit a long beep and automatically returns to Programming mode Step 3 SUPER 32 DT35A wil...

Страница 23: ...903 for 93 Silent Device or 0904 for 94 Non silent Device Enter 0903 for learning in silent devices Enter 0904 for learning in smoke detectors CO detectors pendants fixed emergency transmitters or lon...

Страница 24: ...Plug the PC Programming cable QT cable A into the Programming Telephone Jack of the panel Step 3 Connect QT cable A to the USB port on your computer See Figure 1 for connection diagram between medical...

Страница 25: ...o start programming with Super Tool programming software via USB port To download Super Tool programming software open your browser and type below URL in the address bar https www climax com tw climax...

Страница 26: ...port connected to the panel enter Panel Access Code Default 8744 and then click Open Step 4 A Read All command success message will pop up The current firmware version of the panel will be displayed o...

Страница 27: ...A click on different function tabs to see and edit the panel functions 5 4 1 1 Report The Report tab allows the user to configure report settings Dial Call Reporting Dial Call Reporting is a new repor...

Страница 28: ...ul digital reporting in CID Scancom Tunstall or Franklin 4 2 format and one successful speech reporting If only digital reporting is programmed or only speech reporting is programmed the sequence of r...

Страница 29: ...n Pendant 1 is pressed or triggered under Low Battery status 04 Pendant 2 Emergency with Low Battery When Pendant 2 is pressed or triggered under Low Battery status 05 Pendant 1 Low Battery When Penda...

Страница 30: ...gency Pendant WTR supervision failure status is restored 27 CO Alarm When the Carbon Monoxide Detector CO is triggered 28 CO Alarm Restore When the Carbon Monoxide Detector CO emergency status is rest...

Страница 31: ...o be programmed in this tab This tab is only available when the Others radio button is selected in the Report tab 01 06 Telephone Number Programming 01 06 Used to program the 1st 6th Tel numbers respe...

Страница 32: ...ignaling is set to ON once the Alarm Reporting is completed the HELP BUTTON backlight will start to flash Press the RESET BUTTON when the Help arrives and the panel will report to monitoring center an...

Страница 33: ...8744 as factory default To set a new Access code enter the desired 4 digit number in this field 41 Auto Answer for Remote Programming The Panel can be programmed to auto answer incoming phone calls a...

Страница 34: ...Command 46 that gives the user the ability to speak directly with the Monitoring Center Personnel If either Scancom or Tunstall reporting format is selected the Panel will ignore this field s selecti...

Страница 35: ...anel will dial the telephone number programmed in this field and open two way communication when the call is answered When entering the phone number entering represent a 3 sec pause e g Switchboard sy...

Страница 36: ...High Temperature Reporting threshold in degrees Fahrenheit 32 F 212 F 56 Low Temperature Reporting Set the Low Temperature Reporting threshold in degrees Fahrenheit 32 F 212 F 5 4 1 6 CO2 The CO2 tab...

Страница 37: ...ces The available devices that can be learnt in via Command 93 and 94 are PIR Sensor PIR Smoke Detector SD Carbon Monoxide CO Carbon Dioxide Detector CO2 Temperature Sensor TS Fixed Panic Button PB Wr...

Страница 38: ...is prohibited unless it is removed from the system first 95 Learn In Sensor with Device ID If sensor device ID is given please refer to label sticking on the device or consult the supplier you can le...

Страница 39: ...e command success will pop up 81 Remove Zone 1 Device Click Remove to remove zone 1 device from the Panel A message Remove Zone 1 Device command success will pop up 82 Remove Zone 2 Device Click Remov...

Страница 40: ...he Panel will instantly pick up any call that has 321 as the last 3 digits If a number string 17605851848 is programmed the Panel will instantly pick up any call that has 7605851848 as the last 10 dig...

Страница 41: ...hen Default is selected the Super Tool will display default configurations of the Panel you can use this profile to return the Panel to its default setting New Profile To create a new profile click on...

Страница 42: ...puter Please see pictures below as examples When you use another computer to execute the Super Tool and you wish to apply the configurations of the profiles you created on the old computer please make...

Страница 43: ...40...

Страница 44: ...ts The first digit 1 of the Caller ID will be ignored The 11 th Caller ID is used for disabling enabling system reporting function Please refer to 5 6 Enable Disable System Reporting 6 1 3 AC Power Ch...

Страница 45: ...t reminder Inactivity timer expiring please reset at every 5 minutes to notify the user for 30 minutes When the Mobility timer is not reset after 30 minutes SUPER 32 DT35A will send a Mobility Timer E...

Страница 46: ...ve Guard Time Delay and will be reported immediately SUPER 32 DT35A will play voice prompt Fire Alarm Carbon Monoxide Alarm to inform the user of the alarm at hand During this time period the Control...

Страница 47: ...er 1 to LISTEN IN ONLY Enter 3 to open TWO WAY VOICE COMMUNICATION Enter 5 to HANG UP Enter to TOGGLE 3 TUNSTALL FORMAT Enter C to TALK ONLY Enter to LISTEN IN ONLY Enter 3 to open TWO WAY VOICE COMMU...

Страница 48: ...t to add another 1 30 minutes set by Command 46 To terminate the call press either DTMF 9 or RESET button on SUPER 32 DT35A During the Speech period if there is no any DTMF command pressed the call wi...

Страница 49: ...he learning mode To conduct Walk Test Step 3 Move the device to your desirable location in the house and press the sensor button to observe the range of its operation Step 4 If SUPER 32 DT35A responds...

Страница 50: ...SUPER 32 DT35A Make sure the power cord is still plugged into the DC Jack Step 2 Press the Power Button again to power on SUPER 32 DT35A while holding down both the HELP RESET buttons until one long...

Страница 51: ...re than 10 sec the Green LED flashes every 2 sec with a beep every 30 secs When AC Power for the Medication Dispenser fails and lasts for 24 hours 302 Panel Low battery When SUPER 32 DT35A is under Lo...

Страница 52: ...t Transmitter Emergency Pendant WTR for a pre set period by Command 49 D 1014 Device Low Battery When devices are under Low Battery Status the Green LED flashes every 2 secs with 3 beeps every hour D...

Страница 53: ...eporting 535555557 WTR Supervision Failure Restore WS Emergency Restore When the WTR supervision failure status is restored When WS emergency status is restored 555555558 Device Low Battery When devic...

Страница 54: ...S is restored 88 Periodic Test Report AKA Self test report Global test When the SUPER 32 DT35A reports Periodic test call to monitoring Center When the SUPER 32 DT35A reports Global Test to Monitoring...

Страница 55: ...triggered When Smoke Detector SD button is pressed 08 Fall emergency When the Fall Sensor button is presssed 09 Panel AC Failure When the Panel AC power failure is detected and lasts for more than on...

Страница 56: ...35A is unable to receive the signal transmitted from the Wrist Transmitter Emergency Pendant WTR for a pre set period by Command 4 26 WTR Supervision Restore When the Wrist Transmitter Emergency Penda...

Страница 57: ...status 42 Water Sensor Low Battery Restore When the water sensor battery is back to normal 43 Medication Dispenser Mechanism Jam When the Medication Dispenser is jammed e g White T Bar not in the cor...

Страница 58: ...nce 0 Alternate Reporting Sequence 1 One by One Reporting Sequence Bi Alternate Reporting Sequence 10 Bi Global Account Number 4 to 12 digits Bi No account number 11 Bi 4 12 digits Account number 4 Te...

Страница 59: ...Call Reporting 24 Bi To Set Reporting Method for Tel Number 4 0 Contact ID 1 Scancom 2 Tunstall 3 Speech 4 VRI 6 Franklin 4 2 8 Auto CID Franklin 4 2 9 Dial Call Reporting Note When any of the comman...

Страница 60: ...2mins 03 3mins 04 4mins 05 5mins 06 6mins 07 7mins 08 8mins 09 9mins 10 10mins Bi 2 minutes 47 Bi Off set time 1 1 hour 2 2 hours 3 3 hours 4 4 hours 5 8hours 6 12 hours Bi 1 Hour 49 Bi Supervision 0...

Страница 61: ...device ID Enter Device Type 93 or 94 Device ID Input rule For single digit number enter 0 followed by the number Enter 01 instead of 1 0 9 00 09 A 10 B 11 C 12 D 13 E 14 F 15 Example Device Type 93 De...

Страница 62: ...sensor has been learnt into the Control Panel Power on Played when the Panel is powered on Calling the Care Center Played once after pressing the Help Button on the Control Panel Active Button on Pan...

Отзывы: