32
-
The Guard Time for Fall Sensor’s fall detection function is set separately from regular Guard
Time.
-
The Panel can be programmed to delay alarm reporting (triggered by Fall detection) from
(
00
) (instant reporting) to (
99
) seconds.
-
During Guard Time period, a continuous series of beeps will be emitted to alert user. If a
false alarm is triggered by
Fall Sensor
, it can be cancelled within the Guard Time Delay.
-
The Emergency alarm cannot be cancelled after the Guard Time is elapsed.
-
If an emergency alarm is triggered by pressing the Active Button on Fall Sensor, the guard
time delay time is determined by the setting of “Guard Time Delay (Normal)” instead of the
setting of “Guard Time Delay for Fall Sensor”.
67# Setting the Help Arrived Timer:
-
This is used to set the countdown timer for the Panel to resend the alarm report if no help
has arrived after the initial report is made (meaning the reset button has not been pressed
before the timer expires).
-
The Help Arrived function (Command
33
) must be set as
ON
for this function to work.
75# Help Not Arrived Call:
-
If help has not arrived after sending the alarm report for 4 times, the Panel will dial the
telephone number programmed in this field and open two-way communication when the call
is answered.
-
When entering the phone number, entering (
) represent a 3-sec. pause. (e.g. Switchboard
system, extension, etc.)
-
Up to 20 digits including (
) are allowed for each telephone number.
-
The Help Arrived function (Command 33) must be set as ON for this function to work.
-
The Panel only dials this telephone number once. If this phone call fails, the Panel will not try
again.
76# Call Progress Tone:
-
When turned on, all Call Progress Tones are audible while reporting. Call Progress Tones
include all tones during reporting such as dial tone, DTMF key press tone, ring tone,
handshake, etc.
-
When turned off, Call Progress Tones are disabled and inaudible.
-
This function will be disabled if Silent Mode (Command 35) is enabled, or alarm activation is
made from a Silent Device (learnt using Command #93).
77# No Pendant Learned-in Report:
-
If No Pendant Learned-in Report is set to
“Enable”
, the Panel will send a No Pendant
Learnt-in report to the Monitoring Center when no pendent is learnt into the Panel 30 mins
after powering up. The Panel will repeat every hour thereafter, until a pendant is
successfully learnt in.
-
If No Pendant Learned-in Report is set to
“Disable”
, the Panel will Not send a No Pendant
Learnt-in report to the Monitoring Center.
Содержание SUPER 32-DT35A