19
10 sec
When the
("
TA-TC-TD-TAL-Tb-FTCI-FTCS") inputs
are activated the warning lights will light up.
PRESS PROG
Connect the
programming device
(
CSER) and activate it.
5 sec
10 sec
The segments regarding the command status
(LED “ON” = command active) and safety status
(LED “ON” = safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once
999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "
test" mode (only activated when the motor has
stopped) it is possible to check the status of the
command and safety devices.
The warning lights will activate once, each time a
“
TA-TC-TAL-TD-Tb-FTCI-FTCS”
command
is
received.
In this mode you can activate serial line
communication by using the external program, which
is to be connected to the
CSER connection via cable
(fig. 3).
While communication is active dashes will appear on
the display; after 5 seconds of inactivity you will be
moved back to the "
test" mode.
To return to the normal operating mode press the
“
test” command again and wait for 10 seconds.
PRESS PROG
Memorises the DIP-SWITCH settings and displays
the firmware version e.g. “_
15”
PRESS PROG
PRESS PROG
PRESS PROG
The status of the security devices
Tb, FTCI,
FTCS/CSP
are always shown on the display.
10 sec
Setting the current sensor.
1 = conforms to the standard EN 12453
2 = motor consu 1,2 amps
3 = motor consu 1,8 amps
PRESS PROG
Each time "
PROG" is pressed the
number will increase (from 1 to 3).
10 sec
10 sec
PRESS
PROG
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 3)
DISPLAY MODE
Automatic repositioning
This command is carried out after: a programmer reset; a motor error or an
encoder error. It is indicated by the warning lamps and the indicator light flash-
ing simultaneously for
2 seconds and then switching off for 10 seconds.
After the programmer has been in this condition for
3 minutes it will (after
pre-flashing for
10 seconds) automatically move the gate, slowly, to the
completely closed position (2 times as in the programming procedure) in order
to recover the correct position. At this point the programmer will function
normally. To carry out automatic repositioning without waiting for
3 minutes
you may send a
(TA, TC, TAL or TD) command to the programmer.
The time count for the repositioning start begins from the moment in which
all safety devices are at rest.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another
3 minutes,
press the "
PROG" button.
Using the
PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
- access the "
test" mode;
- setting the current sensor level
.