20
MEMORIZZAZIONE CODICE Tx-Rx
RCQ449100
13-04-2001
DM0531
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
MR
The system can be remotely activated using radio control devices.
Each channel can be set to a maximum of 2 functions:
- function 1: sequential command
- function 2: limited opening command
To set one of the functions to the channels
A-b-C-D use the selection jump-
ers "
J1":
- In position "
A" the first function is active, TD;
- In position "
b" the second function is active TAL.
The command can be set (dip "
1") to work as "open-block-close-block" or
"
open-close".
Memory module (M1)
This is extractable, furnished with a non volatile EEPROM type memory
and contains the transmitter codes and allows you to memorise up to
300
codes.
The programmed codes are maintained in this module even during black-
outs.
Note: Before memorising the transmitters for the first time remember to cancel
the entire memory content.
If the electronic card has to be replaced due to failure, the module can be
extracted from it and inserted into the new card.
Make sure that the module is correctly inserted as shown in fig. 3.
Signal LEDs "L3" (fig. 3):
Flashing quickly:
cancels a single code
Flashing slowly:
memorises a single code
Permanently lit:
memory full.
TRANSMITTER CODE MANAGEMENT
Memorising a channel (fig. 3):
1. Press and hold down button "
P1" MEMO: The LED "L3" will flash slowly.
2. At the same time activate the transmitter which is to be memorised.
3. Hold down button "
P1" MEMO until LED "L3" starts to flash again.
4. Release the button: The LED will continue to flash.
5. Activate the transmitter again (same transmitter, same channel; if the channel
is different or it is a different transmitter the memorisation attempt will abort
without success).
6. End of memorisation: the LED "
L3" will remain lit for 2 seconds, indicating
that the transmitter has been correctly memorised.
Note: It is not possible to memorise a code which is already in memory: if
you attempt this, the LED will switch off when you activate the transmitter
(point 2).
Only after releasing the button "
P1" MEMO will you be able to continue the
memorising procedure.
If after activating the transmitter for the first time you wait for more than fifteen
seconds without activating the transmitter a second time the memorisation
attempt will abort without success.
Cancelling a channel (fig. 3):
1. Press and hold down the button "
P2" DEL: the LED "L3" will flash
quickly.
2. Activate the transmitter channel which is to be cancelled.
3. The LED will remain lit for 2 s, indicating that the transmitter has been can-
celled.
Note: If the user that you wish to cancel is not in memory, the LED will stop
flashing; only after releasing the button "
P2" will you be able to continue the
cancellation procedure.
For both the memorisation and cancellation procedures, if the button is released
before activating the transmitter the procedure will abort.
Cancelling all user codes from memory (fig. 3)
1. Keep both buttons pressed down ("
P1+P2") for more than four seconds.
2. LED "
L3" will remain lit during the entire cancellation time (about 8 sec-
onds).
3. LED "
L3" switches off when the cancellation procedure has terminated.
Note: When the memory is almost full the time required to search for a user
code could take up to 1 second from when the command was received. If led
"L3" remains lit memory is completely full. To memorise a new transmitter you
will first have to cancel a code from memory.
Memorising ulterior channels via radio
• Memorisation can be activated by radio (without opening the receiver con-
tainer) if jumper "
J2" has been inserted (fig. 3).
1. Make sure that the jumper "
J2" has been inserted (fig. 3).
2. Using a transmitter, in which at least one channel button "A, B, C or D" has
already been memorised in the receiver, press the button in the transmitter
as shown in figure.
Note: all the receivers within range when the
channel button is pressed (and which have at
least one of the transmitter channel buttons
memorised) will activate their signal buzzer
"
b1" (fig. 3).
3. Press one of the channel buttons on the same transmitter.
The receivers which do not contain that channel code will sound a five-
second long "beep" and will then deactivate.
The receivers which contain the channel code will sound a one-second long
"beep" and will enter the "
programming via radio" mode.
4. Press the previously chosen channel buttons on the transmitter which you
wish to memorise; the receiver will sound 2 "beeps" of half a second each
after which the receiver will be ready to receive another code.
5. To leave the programming mode wait for 3 seconds without pressing any
buttons.
The receiver will sound a five-second long "beep" and will then exit the
programming mode.
Note: When the memory is entirely occupied the buzzer will sound 10 rapid
"beeps" and will automatically leave the "
programming via radio" mode. Led
"
L3" will remain lit on the receiver.
The same signal is given each time you try to enter "
programming via radio"
when the memory is full.
CONNECTING THE ANTENNA
Connect an
ANS400 tuned antenna using a coaxial cable RG58 (impedance
50
Ω
) with a maximum length of
15 m.
1) Automatic
Selected by enabling automatic reclosing (dip "
2" in position "ON").
When the door is completely closed the opening command will start a
complete cycle which will end with automatic reclosing and the night light
switching off.
Automatic reclosing starts after the programmed pause period has elapsed
(minimum 2 seconds) when the opening cycle has been completed or straight
away after the intervention of a photoelectric cell (the intervention of a photo-
electric cell causes the pause time to be reset).
During the pause time the symbol will flash on the display and pressing
the blocking button during this period will stop automatic reclosing and con-
sequently stop the display from flashing.
The indicator light remains lit until the closing manoeuvre has terminated.
2) Semiautomatic
Selected by deactivating automatic reclosing (dip "
2" in position "OFF"). Work
cycle control using separate opening and closing commands.
When the door has reached the completely open position the system will wait
until it receives a closing command either via an external control button or via
radio control, before completing the cycle.
The indicator light remains lit until the closing manoeuvre has terminated.
REMOTE CONTROL (fig. 3, page 4)