17
Terminal board connection
1-2
Programmer power supply
230 Vac
3-4
Transformer power output
230 Vac
5
Programmer power supply earth wire
5
Motor earth wire
7
Tb (NC contact) stop button input (The opening of this contact inter-
rupts the cycle until a new movement command is given).
8
Common for all inputs and outputs.
9
FTCS (NC contact) Safety and control devices in input (stop photo-
electric cells). The opening of this contact will block all movement, until
the obstruction has been removed, due to the safety device cutting in,
the gate will then continue moving until it reaches a travel limit (only
in the automatic mode).
CSP (NC contact) safety buffer input). Opening this contact will pro-
voke a travel direction inversion of
10 cm, a pause of 3 minutes, after
which the motor will continue moving in the original direction after a
10 second preflashing period has elapsed.
10
FTCI (NC contact) safety and control devices in input (photocells
invert the travel direction when an obstruction is detected). Opening
this contact will provoke a travel direction inversion during closure
due to the cutting in of the safety device.
11
Common for all inputs and outputs.
12
30 Vdc output, powering controlled external loads
(1)
.
13
LP 30 Vdc output for warning lights.
25 W intermittent activation (50%), 12,5 W continuous activation.
14
Common for all inputs and outputs.
15
LS 30 Vdc 3W output for an indicator light.
16
Common for all inputs and outputs.
17
30 Vdc output, powering permanent external loads
(1)
.
18
Common for all inputs and outputs.
19
TA (NO contact) opening button input.
20
Common for all inputs and outputs.
21
TC (NO contact) closing button input.
22
TD (NO contact) dynamic button input.
23
Common for all inputs and outputs.
24
TAL (NO contact) limited opening button input.
25
EMRG 1 (NO contact) emergency manoeuvring button input 1
26
EMRG 2 (NO contact) emergency manoeuvring button input 2
27
Common for both emergency buttons.
28
Outer conductor for the radio receiver antenna
29
Inner conductor for the radio receiver antenna (if an external antenna
is fitted use a coaxial type cable
RG58 with an impedance of 50
Ω
).
Note
(
1
)
The total of the 2 external device outputs must not exceed
10W.
ALL UNUSED NC CONTACTS MUST bE JUMPED.
Switch on the power and make sure that the indicator LEDS are in the following
condition (
note: If the display is off you can press the PROG key to show the
status of the safety devices.
- L1 Power on
ON
- L2 Wrong battery connection
OFF
(1)
- L3 Transmitter code programming indicator
OFF
- L4 Battery charging
OFF
(2)
- L5 Indicator for the blocking button "Tb"
ON
(3)
- L6 Indicator for the inverting photoelectric cells "FTCI"
ON
(3)
- L7 Indicator for the stop photoelectric cells "FTCS"
or a contact safety edge "
CSP"
ON
(3)
- L8 Indicator for the opening button "TA"
OFF
- L9 Indicator for the opening button "TC"
OFF
- L10 Indicator for the limited opening button "TAL"
OFF
- L11 Indicator for the dynamic button "TD/CH1"
OFF
Note
(1)
If this LED is "on" disconnect the battery power cables immediately
and contact the after sales service.
Note
(2)
This LED is "on" when the battery is charged.
Note
(3)
Check that the activation of the safety devices switches the corre-
sponding LEDS off.
If the
green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If
one or more of the safety LEDS do not light up check the contacts of the
relative security devices and check that the unused safety device contacts
have been bridged.
Collegamenti scheda base
SL424E
11-05-2005
DC0398
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
SL424E SCHEDA bASE
(con 6 display a led + manovra di emergenza)
CS1206.01B DC0398
M
P3
M1
E1
R1
b1
J1
L11
L9
L7
L6
L10
L8
L5
1
2
3
4
5
6
7
8
ON
S1
CSER
P2
P1
F4 F10A
F5 F3.15A
F3 F10A
F2 F3.15A
28
29
TRANSFORMER
F1 T1.6A
2
3
1
4
6
5
TRF 230Vac
230Vac
L
N
12
11
10
9
18
17
16
15
14
13
8
7
22
21
20
19
24
23
TA
TD
TC
CMN
CMN
TB
CMN
FTCS
FTCI
LP
CMN
LS
CMN
CTRL
30Vdc
OUT
30Vdc
L4
L1
L3
L2
J3
J2
TAL
CN1
D1
25 26 27
CMN
EMRG 2
EMRG 1
b1
Signal buzzer "
via radio" mode
CN1 Motor Faston connection
CSER Serial line connection (only for diagnostics)
D1
Six-segment LED display
S1
Selection dip-switch
E1
Encoder connection
F1
1.6A delayed fuse (230 Vac motor power protection)
F2
3.15A rapid fuse (24V transformer power protection)
F3
10A rapid fuse (motor power protection from the transformer)
F4
10A rapid fuse (battery powered operation motor protection)
F5
3.15A rapid fuse (24V battery powered operation protection)
J1
Radio channel selection
J2
Enable transmitter memorisation via radio
M1
Transmitter code memory module
P1
Transmitter code memorization button (
MEMO)
P2
Transmitter code cancellation button (
DEL)
P3
Programming button (
PROG)
R1
Radio frequency module,
433 MHz for S449 transmitters