16
- The geared motor unit has been assembled in the fac-
tory to be fitted to the
LEFT SIDE of the gate (internal
view). To install the motor to the
RIGHT of the gate
set dip "
8" of the dip-switch "S1" (fig. 3) to "ON".
Manual release is carried out with the power to the motor interrupted due to
a power failure. To release the gate use the manual release key supplied with
the unit. The key should be kept inside the house in an easily accessible place
or stored with the unit itself.
To release the unit
Remove the cover "
A" using a screwdriver and insert the key "b" over the
T-shaped pin, then rotate the key through 90 degrees in the direction indi-
cated by the arrow "
C" (clockwise). This will release the clutch and separate
the gears from the motor allowing you to manually manoeuvre the gate by
pushing lightly on it.
To relock the unit
Follow the above instructions in reverse order rotating the key through 90
degrees in the direction indicated by the arrow "
D" (anticlockwise). Close the
release mechanism access cover "
A".
Attention! Never use the manual release mechanism while the gate
is in operation. If you release the gate and then give a movement
command the following symbol appears on the display
.
Access to the electronic card
To open the cover insert a screwdriver into the slot "
G" and turn it through
90° as shown in fig. 8.
Caution! Before opening the cover make sure that the power
has been switched off at the mains.
Electronic programmer for a
dc motor with an incorporated radio receiver
card, which allows the memorisation of
300 user codes (see "remote control"
page 20).
The "rolling code" type decoder uses
433.92 MHz series transmitters.
The motor rotation speed is electronically controlled, starting slowly and
increasing in speed; the speed is reduced as it nears the travel limit so as to
enable a controlled smooth stop.
Programming is carried out using one button and allows you to set the current
sensor and the entire gate travel distance.
The logic carries out position control using an encoder.
The intervention of the anticrush/antidrag sensor during the closing and opening
stages causes a brief (
10 cm) travel direction inversion then a block.
• After having installed the device, and
before powering up the
programmer, release the gate (manual release mechanism) and
move it manually, checking that it moves smoothly and has no
unusual points of resistance.
• The programmer can activate the motor automatically. This is
indicated by the warning lights pre-flashing for 10 seconds, and by
the symbol
appearing on the display ("
automatic reposition-
ing" on page 19).
• The programmer is fitted with an electrical input monitoring
system, which is used to block the motor in emergency conditions;
however this system is not active during the first second of each
manoeuvre.
Do not therefore attempt to physically block the door during these
stages.
If you need to check the status of the fuses, disconnect the power
supply to the programmer; reconnect it only after having re-inserted
the fuse.
• The presence of the electrical input monitoring system does
not exclude the need to install photoelectric cells or other safety
devices which are foreseen by the
local standards and regulations
in force.
• The geared motor unit has been assembled in the factory to be
fitted to the left side of the gate. Read the paragraph "
instructions
for positioning the unit".
• For the correct operation of the programmer the incorporated
batteries must be in good condition: the programmer will
lose the
position of the gate in case of blackouts when the batteries are flat,
the alarm will sound and automatic repositioning will take place .
Check the good working order of the batteries every six months
(see page 21 "
battery check").
• Before connecting the appliance make sure that the voltage and
frequency rated on the data plate conform to those of the mains
supply.
• An all pole trip switch with at least
3 mm between the contacts
must be installed between the unit and the mains supply.
• Don't use cables with aluminium conductors; don't solder the
ends of cables which are to be inserted into the binding posts; use
cables marked
T min 85°C and resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both
the wire and the insulating sheath are tightly fastened (a plastic
jubilee clip is sufficient).
ELECTRICAL CONNECTION 230 Vac
• Connect the control and security device
wires.
• Run the
230 Vac mains power supply
through the trip switch "
TS" and the
through the cable clamp "
PS" to the
terminal board:
- connect the live to post 1
L
- connect the earth to post 5
- connect the neutral to post 2
N
If you need to check the status of the fuse "
F1", disconnect
the power supply to the programmer; reconnect it only after
having re-inserted the fuse.
INSTRUCTIONS FOR POSITIONING THE UNIT
MANUAL RELEASE MECHANISM
1 2 3 4 5 6 7 8
ON
SCALA: 1:2
Pr
odotti T
echnocity
SL4024
08-06-98
DI0069
Description
:
Pr
oduct Code
:
Date
:
Drawing number
:
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San V
endemiano (TV) Italy - via Raf
faello, 36 T
el: 0438/401818 Fax: 0438/401831
Draft :
All rights r
eserved. Unauthorised copying or use of the information contained in this document is punishable by law
VIS
TA
IN
TE
R
N
A
C
A
N
C
E
LL
O
S
L4
02
4
7
SCALA: 1:2
Prodotti Technocity
SL4024
11-06-98
DI0130
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Sblocco motore
b
C
D
A
F
90
°
G
8
6
5
2
3
1
4
230Vac
TS
N L
PS
F1 1.6A
T
ELECTRONIC PROGRAMMER
IMPORTANT REMARKS
Содержание 424EBSS