Chapter 9
9-3
A. Flying start temperature control
Applied 15 seconds after receiving flying start. The temperature is adjusted (between 160 deg C and 190 deg C), according to the time elapsed since the previous
job finished. The purpose of this function is to reduce the time required for the first print by adjusting the temperature.
Reference:
Specifically, flying start is initiated with the following timings.
- With the control panel Copy/ Copy (quick) screen displayed, one of the control panel soft keys is touched, one of the numeric keys is pressed, or a cassette is
opened/ closed.
- Common to all function tabs on the control panel, a control panel tab toggle button (soft key) is pressed.
- In some other mode, the device recovers from sleep1 or sleep2.
B. Temperature control after job ends
Drum rotation will stop 5 seconds after a job has finished.
In this control, it is a target temperature control to shorten the print time that hangs to the job since the consecutive second.
The temperature is adjusted (between 160 deg C and 190 deg C), according to the time elapsed since the previous job finished.
F-9-4
C. Standby temperature control
Standby temperature control is applied as follows, when specified in service mode.
Standby temperature control begins once the temperature adjustment after job completion has finished, and continues for up to 15 minutes (but will stop once a
flying start instruction is received). The temperature is adjusted (between 160 deg C and 190 deg C), according to the time elapsed since the previous job finished.
Also, the fixer motor is rotated a prescribed number of times at 1 minute intervals.
The purpose of this function is to reduce the time required for the first print by adjusting the temperature.
service modes:
COPIER>OPTION>BODY>FX-ASTBY
Standby temperature control ON/OFF 0: OFF (default) 1: ON
To increase the time till 1st sheet print, set to [1].
9.2.1.3 Temperature Control during Printing
0014-5558
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
Temperature control during printing regulates temperature from the beginning of the print cycle and until completion. The temperature of the target changes de-
pending on the material kind and the elapsed time and the number of sheets from the print beginning.
The temperature sequence is divided into the following 3 intervals:
- start-up (initial rotation) temperature control
- printing temperature control
- sheet-to-sheet temperature control
F-9-5
A. Start-Up (initial rotation) Temperature Controller
This control has aimed to select an energizing ratio the best so as not to exceed the maximum electric power consumption, and to start up the established machine
up to the temperature of the target in the regulation time.
B. Print Temperature Control
Print temperature control regulates temperature based on the number of sheets printed, paper type and main thermistor output upon activation of start-up control
during continuous printing in order to achieve a target temperature within the prescribed temperature range.
COPY/PRINT
COPY/PRINT
STANDBY
Device status
Fixing temperature
5 sec
FlyingStart
15 sec
Initial rotation
Printing
Sheet-to-sheet
Thermistor
reading
Time
[ t ]
[deg C]
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......