Chapter 17
17-39
17.5 FUNCTION (Operation/Inspection Mode)
17.5.1 COPIER
17.5.1.1 COPIER Table
0013-9278
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
1. INSTALL
T-17-41
COPIER>FUNCTION>INSTALL
Sub item
Description
level.
STIR-4
This mixes the developing solutions inside the developers of all the colors.
The Y, M, C and Bk developers are raced for two minutes to ensure that the developing solutions are mixed.
1
STRD-POS
Automatic detection of CCD scanning position in DF stream reading
1
CARD
Used to make card reader installation settings.
Setting values
1 to 2001 [Factory default/After RAM clear: 1]
Operation method Enter the number of cards to use. (You can use up to 1,000 cards from the entered number.)
Initialize the card management information.
- Initialize the card name (department ID) (from the entered number).
- Initialize the card's password.
1
KEY
Used to set management key function recognition.
Setting values
0: Don't recognize management key function (value at time of factory shipment).
1: Recognize management key function.
Operation method
1) Select COPIER > INSTALL > KEY, then enter '1'
2) Turn the main power switch OFF/ON (the management key function is now recognized).
1
AINR-OFF
Walm-up-rotation disable setting at initial installation
This disables the initialization of the P-CRG which is performed when a new P-CRG has been inserted. It prevents the
fuse from blowing when the P-CRG initialization has been completed.
It is used when replacing the P-CRG and checking the images in situations when, for instance, the causes of trouble are
identified. When it is set to "1," the initialization is canceled and the fuse is not blown even when a new P-CRG has been
inserted.
Settings
0: Initialization is performed when a new unit is inserted. The fuse is blown.
1: Initialization is not performed when a new unit is inserted.
[Factory setting/value after clearing RAM: 0]
1
E-RDS
E-RDS settings
Setting values
0: Not in use
1: In use
[Factory settings and after RAM clear: 0]
1
RGW-PORT
Specify port number of sales company server used in E-RDS
Setting range: 1 to 65535
[Factory settings and after RAM clear: ]
1
COM-TEST
Check connection with sales company server used in E-RDS
Checks sales company server connection. Judges whether connection can be made and displays the results as OK or
FAIL.
1
COM-LOG
Display detailed results of communication test with sales company server used in E-RDS
Displays information on any errors that have occurred in connection with sales company server.
1
RGW-ADR
Specify URL of sales company server used in E-RDS
Sets sales company server URL.
1
CNT-DATE
Set timing of counter transmission to server
Sets time and date for start of transmission of counter information to server, via E-RDS third party extension function.
Setting range: YYYYMMDDHHMM (YYYY: year, MM: month, DD: date, HH: hours, MM: minutes)
[Factory settings and after RAM clear::000000000000]
Note
This item is only displayed when the E-RDS third party extension function is enabled.Set timing of counter transmission
to server
Sets time and date for start of transmission of counter information to server, via E-RDS third party extension function.
Setting range: YYYYMMDDHHMM (YYYY: year, MM: month, DD: date, HH: hours, MM: minutes)
[Factory settings and after RAM clear:: 000000000000]
Note
This item is only displayed when the E-RDS third party extension function is enabled.
1
CNT-INTV
Set interval of counter transmission to server
Sets transmission intervals for transmission of counter information to server, via E-RDS third party extension function.
1
INIT-Y
Y color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
2
INIT-M
M color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
2
INIT-C
C color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
2
INIT-K
K color toner density signal (SGNL, REF) initial value reading
This is used when more than 100 sheets have passed through in error with a new CRG used in investigating image
defects, etc.
2
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......