Chapter 17
17-24
50-RG
Display the offset value for color misalignment (between RGs) at 50% reading in the BOOK mode.
Adjustment method:
When executing RAM clear for the reader controller PCB or replacing the reader controller PCB, enter the value
indicated on the service label.
Setting range: -150 to 150
[Factory setting value/Value after RAM clear: 0]
MEMO:
When you changed this setting, enter the new value on the service label.
1
50-GB
Use it to indicate the degree of offset (color displacement; GB) for book mode at 50% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
100-RG
Use it to indicate the degree of offset (color displacement; RG) for book mode at 100% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
100-GB
Use it to indicate the degree of offset (color displacement; GB) for book mode at 100% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
50DF-RG
Use it to indicate the degree of offset (color displacement RG) for ADF mode at 50% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
50DF-GB
Use it to indicate the degree of offset (color displacement; GB) for ADF mode at 50% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
100DF-RG
Use it to indicate the degree of offset (color displacement; RG) for ADF mode at 100% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
100DF-GB
Use it to indicate the degree of offset (color displacement; GB) for ADF mode at 100% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
DFTAR-R
Use it when entering the shading target value (red) for use when the DF is used (i.e., normal original read position).
Method of Adjustment
- COPIER>FUNCTION>CC>WLVL1/DF-WLVL2
if the image has a fault when the foregoing service mode item has been executed (e.g., as caused by soiling of the chart),
enter the factory measurement using this mode item.
- if you have initialize the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: 1 to 2047 [Factory default/After RAM clear: 1106]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
DFTAR-G
Use it when entering the shading target (green) for the DF (normal original reading position).
Method of Adjustment
- COPIER>FUNCTION>CD>DF-WLVL1/DF-WLVL2
if the image starts to develop a fault after executing the foregoing service mode item (e.g., as caused by soiling of the
chart), enter the factory measurement using this mode.
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
Range of Adjustment: 1 to 2047 [Factory default/After RAM clear: 1131]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
COPIER>ADJUST>CCD
Sub item
Description
level.
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......