Chapter 10
10-9
T-10-10
*1 Service mode:
COPIER > OPTION > BODY > WUEV-LIV
Default: 15 sec
Setting range: 10 to 600 sec
3. AC Off Mode
The machine remains in this sate when its main power switch remains off. All its power remain off.
10.4.5.2 Power Supply Control
0013-8674
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
The machine's power supply conditions are as follows:
T-10-11
10.4.5.3 SNMP setup
0013-8675
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
When the machine is used as a Windows printer, enabling 'Use SNMP' causes the operating system to collect machine status information at specific intervals, pre-
venting the machine from starting a sleep state.
To avoid the situation, disable the setting (Windows' printer properties).
-Disabling 'Use SNMP'
1) Select 'Configure Port' on the Ports screen (printer properties).
Sleep mode
Shift
The machine moves through different sates in response to the passage of times selected in
Additional Function or in response to a press on the control panel software power switch.
Description
In sleep mode 1, the DC controller PCB and the main controller PCB are supplied with
power. In sleep mode 2, the main controller PCB is supplied with power. In both sleep modes
1 and 2, the power to the fixing AC heater is off.
Also, if there is a network communication and RTC communication during the sleep mode
2, the machine can recover without booting the HDD. When booting the HDD, sleep mode
1, the protection time (120 min) to protect the HDD duration number must be retained. Power
consumption can be kept at low level by not booting the HDD.
When there is network communication and RTC communication during sleep mode 2, the
machine recovers as CPU recovery status (without booting HDD). If there is no Network
communication for 15 sec after the recovery of CPU, the machine transits to sleep mode 2.
If there is a network communication during 15 sec after recovery, the machine transits to
sleep mode 2 after service mode setting time (*1) from the last network communication.
Copy / stand-by
mode
Low-power / sleep 1
mode
Sleep 2 mode
AC OFF mode
remote 1
ON
ON
OFF
OFF
remote 2
ON
OFF
OFF
OFF
ACC power supply PCB
non-all night
24VA
ON
OFF
OFF
OFF
Printer power supply PCB
non-all night
24VU1
ON
OFF
OFF
OFF
non-all night
24VU2
ON
OFF
OFF
OFF
non-all night
24VU3
ON
OFF
OFF
OFF
all night
13VB
ON
ON
ON
OFF
Controller power supply PCB
non-all night
24VU1
ON
OFF
OFF
OFF
non-all night
24VU2
ON
OFF
OFF
OFF
non-all night
13VA1
ON
ON
OFF
OFF
non-all night
13VA2
ON
OFF
OFF
OFF
all night
13VB
ON
ON
ON
OFF
non-all night
12VA
ON
ON
OFF
OFF
non-all night
5VA
ON
ON
OFF
OFF
non-all night
3VA
ON
ON
OFF
OFF
All-night power supply PCB
all night
3VB
ON
ON
ON
OFF
G3 FAX accessory
non-all night
+5V
ON
ON
OFF
OFF
all night
+5VS
ON
ON
ON
OFF
non-all night
+3.3V
ON
ON
OFF
OFF
all night
+3.3VS
ON
ON
ON
OFF
FAX accessory
non-all night
pseudo CI
ON
OFF
OFF
OFF
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......