Chapter 9
9-11
9.4.2 Fixing System Error Code
0013-8530
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
T-9-11
Code
Description
Corrective action
E001
Fixing high temperature error
0000 Condition
The reading of the main thermistor is 260 deg C or more.
Cause
The main thermistor is faulty. The DC PCB is faulty.
- Replace the fixing sleeve unit (main thermistor).
- Replace the DC controller PCB. *1
0001 Condition
The reading of the sub thermistor is 290 deg C or more.
Cause
The sub main thermistor is faulty. The DC PCB is faulty.
- Replace the fixing sleeve unit (sub thermistor).
- Replace the DC controller PCB. *1
0002 Condition
The safety circuit (of the DC controller) has detected a high temperature error
(about 260 deg C or more).
Cause
The thermal switch is faulty. The low-temperature power supply PCB is
faulty. The DC PCB is faulty.
Replace the DC controller PCB. *1
E003
Fixing low temperature error
0000 Condition
In 20 sec after the fixing heater has gone on, the reading of the main thermistor
is 120 deg C or less.
Cause
The main thermistor is faulty. The DC controller is faulty. The connector has
poor contact, or the harness is faulty.
- Replace the fixing sleeve unit (main thermistor).
- Replace the DC controller PCB. *1
0001 Condition
In the course of printing temperature control, the reading of the sub thermistor
is 80 deg C or less for 2 sec or more.
Cause
The sub thermistor is faulty. The DC controller PCB is faulty. The connector
has poor contact, or the harness is faulty.
- Replace the fixing sleeve unit (sub thermistor).
- Replace the DC controller PCB. *1
0002 Condition
During initial rotation, the reading of the main thermistor is 50 deg C or less
0.2 sec after the start of temperature control.
Cause
The DC controller PCB is faulty. The connector has poor contact, or the
harness is faulty.
- Replace the fixing sleeve unit (main thermistor).
- Replace the DC controller PCB. *1
E004
Thermistor is not connected
0000 During walm-up rotation, the thermistor connection signal (FUSER CNCTX)
is open.
- Confirm the cable connection
- Replace the cable exchange, and established
- Replace the fixing unit
- Replace the DC controller PCB.
E009
Error in pressure/release of fixing film unit
0001 In case that the output of fixing automatic pressure phase sensor is not changed
although rotating/reversing the fixing motor
- Check the pressure/release mechanism. Check the connection of the
connector.
- Replace the motor.
E808
Low-voltage power supply circuit fault (zero-cross error)
0000 The low-voltage power supply circuit fault (zero-cross error)
Cause
The low-voltage power supply PCB is faulty. The DC controller PCB is faulty.
- Replace the low-voltage power supply PCB.
- Replace the DC control PCB.
E840
Fan shutter error
0000 Fan shutter open/close operation Error
Cause
Abnormal rotation of the fan shutter motor
Defect of the fan shutter position sensor
Defect of the fan shutter home position error
Defect of the DC controller PCB
- Replace the fan shutter motor
- Replace the fan shutter position sensor
- Replace the fan shutter home position sensor
- Replace the DC controller PCB
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......