Chapter 17
17-28
5. DENS
Concentration of developer in developer unit.
T-17-29
REG-H-C
Coarsely adjust the writing position (in the main scanning direction) of the pattern for C
Offset the writing position of C-color images (in the main scanning direction) in the unit of pixel. Use this item to adjust
color misalignment in the main scanning direction in the unit of pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-H-K
Coarsely adjust the writing position (in the main scanning direction) of the pattern for K
Offset the writing position of K-color images (in the main scanning direction) in the unit of pixel. Use this item to adjust
color misalignment in the main scanning direction in the unit of pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-HS-Y
Finely adjust the writing position (in the main scanning direction) of the pattern for Y
Offset the writing position of Y-color images (in the main scanning direction) in the unit of 1/16 pixel. Use this item to
adjust color misalignment in the main scanning direction in the unit of 1/16 pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-HS-M
Finely adjust the writing position (in the main scanning direction) of the pattern for M
Offset the writing position of M-color images (in the main scanning direction) in the unit of 1/16 pixel. Use this item to
adjust color misalignment in the main scanning direction in the unit of 1/16 pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-HS-C
Finely adjust the writing position (in the main scanning direction) of the pattern for C
Offset the writing position of C-color images (in the main scanning direction) in the unit of 1/16 pixel. Use this item to
adjust color misalignment in the main scanning direction in the unit of 1/16 pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-HS-K
Finely adjust the writing position (in the main scanning direction) of the pattern for K
Offset the writing position of K-color images (in the main scanning direction) in the unit of 1/16 pixel. Use this item to
adjust color misalignment in the main scanning direction in the unit of 1/16 pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-V-Y
Coarsely adjust the writing position (in the sub scanning direction) of the pattern for Y
Offset the writing position of Y-color images (in the sub scanning direction) in the unit of pixel. Use this item to adjust
color misalignment in the sub scanning direction in the unit of pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-V-M
Coarsely adjust the writing position (in the sub scanning direction) of the pattern for M
Offset the writing position of M-color images (in the sub scanning direction) in the unit of pixel. Use this item to adjust
color misalignment in the sub scanning direction in the unit of pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-V-C
Coarsely adjust the writing position (in the sub scanning direction) of the pattern for C
Offset the writing position of C-color images (in the sub scanning direction) in the unit of pixel. Use this item to adjust
color misalignment in the sub scanning direction in the unit of pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
REG-V-K
Coarsely adjust the writing position (in the sub scanning direction) of the pattern for K
Offset the writing position of K-color images (in the sub scanning direction) in the unit of pixel. Use this item to adjust
color misalignment in the sub scanning direction in the unit of pixel.
Setting range: -128 to 127
[Factory setting value/Value after RAM clear: 0]
1
COPIER>ADJUST>DENS
Sub item
Description
level.
SGNL-Y
Display the Y-color toner density signal value when executing "INIT" for ATR control.
Display the Y-color toner density signal value when executing ATR-INIT, which is implemented at PCRG initialization.
Use this item to determine a cause of a density fault.
When replacing the DCON PCB, enter the unique ATR-INIT value for each PCRG.
Setting range: 0 to 65535
[Factory setting value/Value after RAM clear: 0]
1
SGNL-M
Display the M-color toner density signal value when executing "INIT" for ATR control.
Display the M-color toner density signal value when executing ATR-INIT, which is implemented at PCRG initialization.
Use this item to determine a cause of a density fault.
When replacing the DCON PCB, enter the unique ATR-INIT value for each PCRG.
Setting range: 0 to 65535
[Factory setting value/Value after RAM clear: 0]
1
SGNL-C
Display the C-color toner density signal value when executing "INIT" for ATR control.
Display the C-color toner density signal value when executing ATR-INIT, which is implemented at PCRG initialization.
Use this item to determine a cause of a density fault.
When replacing the DCON PCB, enter the unique ATR-INIT value for each PCRG.
Setting range: 0 to 65535
[Factory setting value/Value after RAM clear: 0]
1
SGNL-K
Display the K-color toner density signal value when executing "INIT" for ATR control.
Display the K-color toner density signal value when executing ATR-INIT, which is implemented at PCRG initialization.
Use this item to determine a cause of a density fault.
When replacing the DCON PCB, enter the unique ATR-INIT value for each PCRG.
Setting range: 0 to 65535
[Factory setting value/Value after RAM clear: 0]
1
COPIER>ADJUST>IMG-REG
Sub item
Description
level.
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......