Chapter 17
17-23
F-17-16
2. CCD
T-17-26
COPIER>ADJUST>CCD
Sub item
Description
level.
W-PLT-X/Y/Z
Use it when entering the white label data indicated on the standard white plate.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB, enter the value
indicated on the service label.
- if you have replaced the copyboard glass, enter the value indicated on the copyboard glass. (See the figure below)
Range of Adjustment: 1 to 9999
[Factory default/After RAM clear: W-PLT-X=8244: W-PLT-Y=8707: W-PLT-Z=9383]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
CCDU-RG
Use it to correct color displacement in sub scanning direction between RG associated with the CCD unit.
Method of Adjustment
- if you have initialized the RAM on the reader controller or replaced the reader controller PCB, enter the value indicated
on the service label.
Range of Adjustment: -150 to 150 [Factory default/After RAM clear: 0]
Attention:
If you have changed the setting, be sure to record the new setting on the service label.
1
MTF-MG
Enter the MTF correction value in the main scanning direction.
Adjustment method:
- When executing RAM clear for the reader controller PCB or replacing the reader controller PCB, enter the value
indicated on the service label .
- When replacing the CIS unit, enter the value indicated on the label attached to the CIS unit.
Setting range: 0 to 99
[Factory setting value/Value after RAM clear: 0]
Attention:
When you changed this setting, enter the new value on the service label.
1
MTF-SG
Enter the MTF correction value in the sub scanning direction.
Adjustment method:
- When executing the RAM clear for the reader controller PCB or replacing the reader controller PCB, enter the value
indicated on the service label.
- When replacing the CIS unit, enter the value indicated on the label attached to the CIS unit.
Setting range: 0 to 99
[Factory setting value/Value after RAM clear: 0]
Attention:
When you changed this setting, enter the new value on the service label.
1
BOOK-RG
Enter the offset value for color misalignment caused by the copyboard glass.
Adjustment method:
- When executing RAM clear for the reader controller PCB or replacing the reader controller PCB, enter the value
indicated on the service label.
- When replacing the copyboard glass, enter the numeric value indicated on the copyboard glass.
Setting range: -150 to 150
[Factory setting value/Value after RAM clear: 0]
Attention:
When you changed this setting, enter the new value on the service label.
1
DF-RG
Enter the offset value for color misalignment caused by the stream reading glass.
Adjustment method:
- When executing RAM clear for the reader controller PCB or replacing the reader controller PCB, enter the value
indicated on the service label.
- When replacing the stream reading glass, enter the numeric value indicated on the stream reading glass.
Setting range: -150 to 150
[Factory setting value/Value after RAM clear: 0]
Attention:
When you changed this setting, enter the new value on the service label.
1
Document
Read start position
Vertical size plate
Decreasing setting value
(read start position moves
away from you)
Increasing setting value
(read start position
moves toward you)
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......