Chapter 12
12-1
12.1 RDS
12.1.1 Application operation mode
0013-8731
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
Serviceman selects the operation mode of OFF/ON by the setting in e-RDS setting screen of the service mode. (Menu Screen: E-RDS)
- OFF (default): e-RDS doesn't operate.
- ON: e-RDS operates every function.
12.1.2 Service Center URL and Port Specification
0013-8732
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
The URL and the port number of the equipment information destination can be specified as follows.
- Default (specified beforehand)
- Specified by the service mode. (Menu Screen: RGW-ADR, RGW-PORT)
12.1.3 Communication test
0013-8733
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
Serviceman can distinguish the communication status with the UGW by executing the communication test in the service mode (Menu Screen: COM-TEST), and
referring to the communication log
Error information is displayed in the latest communication log at communication error.
12.1.4 Communication log
0013-8734
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
The list of the log of the communication error (proxy server error etc.)(For 30) can be displayed in display panel in the service mode. (Menu Screen: COM-LOG)
12.1.5 Detailed Communication log
0013-8735
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
Detailed information of the error in the communication log can be displayed in display panel. (Log List Screen: Each error)
12.1.6 SOAP communication function
0013-8736
/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
The following processing is achieved by the SOAP communication (SSL client communication).
e-RDS does the host authentication by using the CA*1 certificate of the VeriSign Co..
When the host certificate or the CA certificate is expired, e-RDS doesn't connect to UGW.
*1: CA: Certificate Authority: Organization that issues electronic certificate used by electronic commerce etc
(1) Communication test:
- Do the communication test
(2) Regularly collect the following data, and transmit it.
- Copy Counter
- Service mode counter
- Parts counter
- Mode Counter
- ROM version
- Scheduling information
- Application log
(3) When jam or alarm/service call error is detected from the device, e-RDS transmits to UGW.
- Transmission of alert code(Counter information is transmitted at the same time. )
When the state of the device changes, e-RDS sends the alert code list.
The main alert codes used are Toner LOW/OUT, Jam, and Door open.
When recovering from an error, e-RDS transmits data that shows the recovering from an error again.
- Transmission of Jam log (Counter information is transmitted at the same time.)
- Transmission of Alarm log (Counter information is transmitted at the same time.)
- Transmission of Service Call (Error code) log (Counter information is transmitted at the same time.)
(4) Change of the device scheduling information
- Scheduling information can be changed by the instruction from UGW.
List of Transmissions:
Content of transmission
Transmission timing
Communication test
When Service mode of device is executed
Copy counter collection/transmission
Every 6 hours
Service mode counter collection/transmission
Every 6 hours
Mode counter collection/transmission
Every 6 hours
Parts counter collection/transmission
Every 6 hours
ROM version transmission
Every 6 hours
Application log
When the log file size exceeds 10kbytes
Содержание iR C2880 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction ...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation ...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller ...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System ...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69 ...
Страница 189: ...Chapter 6 Laser Exposure ...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation ...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System ...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System ...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 11 ...
Страница 359: ...Chapter 11 MEAP ...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS ...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection ...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Страница 421: ...Chapter 14 Standards and Adjustments ...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images ...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis ...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode ...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading ...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools ...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2 ...
Страница 606: ......
Страница 609: ...Aug 29 2006 ...
Страница 610: ......