Section 10. Utilities Installed with LoggerNet
Stay On Schedule
– By default, when LoggerNet has missed a scheduled poll
because of some condition (i.e. LoggerNet was closed, scheduled polling was
disabled, the schedule was paused from the Status Monitor, etc.), once the
condition that prevented polling is no longer true, if an entire poll interval has
elapsed since the last attempt, LoggerNet will immediately try to perform a
poll. In some cases, this may not be the desired behavior. Selecting the Stay
On Schedule check box will cause LoggerNet to always wait until the next
even
Normal Poll Interval
to perform a poll.
Base Date
– Enter a date and a time that the first polling attempt for the device
should occur. If the date and time reflected by these fields has already passed,
polling will be attempted immediately when the schedule is enabled.
Normal Poll Interval
– Enter the interval on which data should be collected
from the device.
Primary Retries Interval
– Enter the interval at which primary retries will
take place. The collection schedule will switch to primary retries when a
communication or other error prevents a “normal” collect attempt from being
completed.
Max Primary Retries –
Enter a value for the maximum number of data
collection attempts that should be made using the
Primary Retries Interval
.
Once the number of primary retries is exhausted, data collection will be
attempted on the
Secondary Retries Interval
if it is enabled. Otherwise, data
collection attempts will continue to be made on the
Normal Poll Interval
.
Secondary Retries Interval –
Enter the interval at which secondary retries
will take place.
Do Secondary Retries
– Select this check box to enable secondary retries
when primary retries are exhausted. If this checkbox is not checked, the
collection schedule for the device will return to the
Normal Poll Interval
after
primary retries are exhausted even if none of those retries succeeded.
Tables to Collect –
This check list box specifies shows a check box for each
“table” that can be collected from the RWIS station that specifies whether that
table will be polled as part of scheduled collection. For more information on
available tables, refer to the online help.
File Open Mode
– Specify, for the selected table, the method for writing the
table data to an output file when it is polled. Options for this control include
the following:
do not create
– No file will be created for the selected table.
append to existing
– If a data file already exists for the selected
table, new data records will be appended to the end of that file.
Otherwise, a new data file will be created.
overwrite existing
– Any existing data file for the selected table will
be overwritten each time that a new record is collected.
10-14
Содержание LoggerNet
Страница 2: ......
Страница 30: ...Preface What s New in LoggerNet 4 xxvi...
Страница 32: ...Section 1 System Requirements 1 2...
Страница 44: ...Section 2 Installation Operation and Backup Procedures 2 12...
Страница 136: ...Section 4 Setting up Datalogger Networks 4 80...
Страница 227: ...Section 7 Creating and Editing Datalogger Programs 7 9...
Страница 298: ...Section 7 Creating and Editing Datalogger Programs 7 80...
Страница 402: ...Section 9 Automating Tasks with Task Master 9 12...
Страница 406: ...Section 9 Automating Tasks with Task Master 9 16...
Страница 450: ...Section 11 Utilities Installed with LoggerNet Admin and LoggerNet Remote 11 22...
Страница 454: ...Section 12 Optional Client Applications Available for LoggerNet 12 4...
Страница 462: ...Section 13 Implementing Advanced Communications Links 13 8...
Страница 482: ...Section 14 Troubleshooting Guide 14 20...
Страница 570: ...Appendix F Calibration and Zeroing F 16...
Страница 578: ...Appendix G Importing Files into Excel G 8...
Страница 579: ......