Section 8. Working with Data Files on the PC
8.2.3.1.4 Stop Condition
The Stop Condition specifies when to stop processing data. This feature allows
segments of data to be removed from large data files. For instance, if a data
file contains one month of data and just one day is desired, the start and stop
values allow the user to get just that day’s data.
The Stop Condition is expressed with the same syntax as the Start Condition.
If the Stop Condition parameter is left blank, Split will execute until the end of
the file. As with the Start Condition, logical “and” and “or” statements can be
used when specifying the Stop Condition (Section 8.2.3.1.3,
Start Condition
),
as well as stopping based on PC time.
The array or record containing the Stop Condition is not included in the output
file. If the stop value is not found, Split will display a dialog box that gives the
option to select a new file and continue processing the data. This feature is
useful when data are contained in more than one data file.
The “Start-Stop On/After Time” function can be used with a Stop Condition.
This will stop processing of the file when the exact time is found or at the first
instance of data after that time has occurred. This option is found on the
Output tab, Other button.
The C and F commands alter the meaning of the Stop Condition.
8.2.3.1.4.1 “C” Option: Formatting Event Tests Containing Conditional Output Arrays
The C option is used to combine data from two or more conditional arrays onto
one Split output line. A conditional array is one that is only output when a
defined event occurs.
Assume that two or more conditional Output Arrays with unique Output Array
IDs compose a test period, followed by an unconditional Output Array that
defines the end of a test. The unconditional “end of test” Output Array is at the
end of each test, but the conditional Output Arrays may or may not be present.
The data file is comprised of several of these tests.
As an example, let’s look at a vehicle test application. The start of the test is
when the vehicle is turned on, and the end of the test is when the vehicle is
turned off. The conditional output arrays could be:
•
monitoring the engine temperature and outputting data to a unique array
when the temperature exceeds a limit
•
outputting data to a unique array when the brakes are applied
•
outputting data when engine RPM exceeds a limit
The unconditional array data (the stop condition) would be output to a unique
array when the engine is turned off. By processing the data with Split using the
C option, the data collected during each test could be merged on to one line,
with blanks inserted if a set of data didn’t exist (e.g., if the engine temperature
never exceeded the defined limit).
•
An Input File must be set up for each array ID in the test. The first Input
File is configured on the Input File tab that appears when you open Split.
8-49
Содержание LoggerNet
Страница 2: ......
Страница 30: ...Preface What s New in LoggerNet 4 xxvi...
Страница 32: ...Section 1 System Requirements 1 2...
Страница 44: ...Section 2 Installation Operation and Backup Procedures 2 12...
Страница 136: ...Section 4 Setting up Datalogger Networks 4 80...
Страница 227: ...Section 7 Creating and Editing Datalogger Programs 7 9...
Страница 298: ...Section 7 Creating and Editing Datalogger Programs 7 80...
Страница 402: ...Section 9 Automating Tasks with Task Master 9 12...
Страница 406: ...Section 9 Automating Tasks with Task Master 9 16...
Страница 450: ...Section 11 Utilities Installed with LoggerNet Admin and LoggerNet Remote 11 22...
Страница 454: ...Section 12 Optional Client Applications Available for LoggerNet 12 4...
Страница 462: ...Section 13 Implementing Advanced Communications Links 13 8...
Страница 482: ...Section 14 Troubleshooting Guide 14 20...
Страница 570: ...Appendix F Calibration and Zeroing F 16...
Страница 578: ...Appendix G Importing Files into Excel G 8...
Страница 579: ......