Preface — What’s New in LoggerNet 4?
New sensor files have been added for the CMP3 Pyranometer, the IRR-P
Precision Infrared Temperature Sensor, the JC Ultrasonic Depth Sensor, the
CNR2 Net Radiometer, the CS106 Barometric Pressure Sensor, the OBS-3+
Turbidity Sensor, the 03002 Wind Speed and Direction Sensor, the 105E
(chromel-constantan) Thermocouple, the WindSonic1 (RS-232) Two-
Dimensional Ultrasonic Wind Sensor, the WindSonic4 (SDI-12) Two-
Dimensional Ultrasonic Wind Sensor, the HMP155 Temperature and Relative
Humidity Sensor, the SR50A Sonic Ranging Sensor (SDI-12 Output), the
CS450/455 Pressure Transducer, a Vibrating Wire Sensor (for generic
vibrating wire sensors and the AVW200), and a saturation vapor pressure
calculation
An Advanced tab has been added to the Finish screen for CRBasic dataloggers,
which allows the user to view the CRBasic code and launch the CRBasic
Editor.
There is now an option to send the program to the datalogger from the Results
tab on the Finish screen.
The user now has the ability to create custom sensor files using existing sensor
files as templates.
The user can now manually set advanced outputs to high or low resolution.
The Add Device button has been removed. Peripheral devices are now listed in
and selected directly from the Available Sensors and Devices tree.
CRBasic Editor
The CRBasic Editor now gives you the option to Save and Encrypt a file.
Encrypted files can be compiled in the datalogger but cannot be read by a user.
Dim variables can now be declared within a subroutine or function and are
local to that subroutine or function. The same variable name can be used within
other subroutines or functions or as a global variable without conflict. The F9
and F10 pop-up pick list will include the local variables for a specific
subroutine or function if the cursor is within that subroutine or function.
F11 can now be used to bring up a pop-up pick list that contains all user-
defined functions found in the program.
A new button has been added to the toolbar (blue arrow) which takes the cursor
to user-defined functions and subroutines.
A new shortcut, CTRL-Y, has been added that will delete the current line.
Several options have been added to the Editor Preferences dialog box
including:
Variable Name Matching – When enabled variable names will be
capitalized based on how they are declared in the program, regardless of
how the user may have typed them.
Create .TDF File at Compile – The user can then associate a .TDF file
with a datalogger. This can be useful if communication is taking place
xxi
Содержание LoggerNet
Страница 2: ......
Страница 30: ...Preface What s New in LoggerNet 4 xxvi...
Страница 32: ...Section 1 System Requirements 1 2...
Страница 44: ...Section 2 Installation Operation and Backup Procedures 2 12...
Страница 136: ...Section 4 Setting up Datalogger Networks 4 80...
Страница 227: ...Section 7 Creating and Editing Datalogger Programs 7 9...
Страница 298: ...Section 7 Creating and Editing Datalogger Programs 7 80...
Страница 402: ...Section 9 Automating Tasks with Task Master 9 12...
Страница 406: ...Section 9 Automating Tasks with Task Master 9 16...
Страница 450: ...Section 11 Utilities Installed with LoggerNet Admin and LoggerNet Remote 11 22...
Страница 454: ...Section 12 Optional Client Applications Available for LoggerNet 12 4...
Страница 462: ...Section 13 Implementing Advanced Communications Links 13 8...
Страница 482: ...Section 14 Troubleshooting Guide 14 20...
Страница 570: ...Appendix F Calibration and Zeroing F 16...
Страница 578: ...Appendix G Importing Files into Excel G 8...
Страница 579: ......