Section 7. Creating and Editing Datalogger Programs
7.4.14 Final Storage Area 2
The ring memory for CR10, CR10X, CR510, and CR23X dataloggers can be
divided into two final storage areas. By default, all memory is allocated to
final storage area 1. However, the datalogger’s memory can be partitioned into
two final storage areas using this option. To allocate memory to Final Storage
Area 2, enter the number of locations into the Final Storage Area 2 Locations
field.
Final storage area 1 is reduced by the amount of memory allocated to final
storage area 2. Data stored in final storage area 2 is protected when Input
and/or Intermediate Storage is reallocated. Data stored in final storage area 1 is
erased when any of the memory areas are reallocated.
7.4.15 DLD File Labels
This option allows you to determine the labels that are saved in the DLD file
for the datalogger. While labels are useful, they can increase the size of the
datalogger program considerably. If program size is a concern, you can limit
or completely eliminate the labels that are saved in the DLD file.
7.4.15.1 Mixed-array Dataloggers
Mixed-array dataloggers can store the labels for input locations and final
storage output in the DLD file. LoggerNet uses this information on the
Monitor Values displays. If you do not include these labels in the DLD file,
you will see generic names for input locations, and will not be able to display
final storage locations at all.
Options for mixed-array dataloggers are:
Minimize DLD Size
– No input location labels or final storage labels are
saved in the DLD file.
Default
– Up to 255 input location labels and all final storage labels are
saved in the DLD file.
All
– All input location labels and all final storage labels are saved in the
DLD file.
7.4.15.2 Table-Based Dataloggers
Table-based (both TD and PB) dataloggers store all final storage labels in the
DLD file and there is no option to remove or reduce them. If you do not
include input location labels in the DLD file, you will not be able to display
input locations on the displays in the software.
The label options for table-based dataloggers are:
Include All Input Location Labels
– All input location labels are saved
in the DLD file.
Include First X Input Location Labels
– Allows you to specify a certain
number of input location labels to be saved in the DLD file.
7-74
Содержание LoggerNet
Страница 2: ......
Страница 30: ...Preface What s New in LoggerNet 4 xxvi...
Страница 32: ...Section 1 System Requirements 1 2...
Страница 44: ...Section 2 Installation Operation and Backup Procedures 2 12...
Страница 136: ...Section 4 Setting up Datalogger Networks 4 80...
Страница 227: ...Section 7 Creating and Editing Datalogger Programs 7 9...
Страница 298: ...Section 7 Creating and Editing Datalogger Programs 7 80...
Страница 402: ...Section 9 Automating Tasks with Task Master 9 12...
Страница 406: ...Section 9 Automating Tasks with Task Master 9 16...
Страница 450: ...Section 11 Utilities Installed with LoggerNet Admin and LoggerNet Remote 11 22...
Страница 454: ...Section 12 Optional Client Applications Available for LoggerNet 12 4...
Страница 462: ...Section 13 Implementing Advanced Communications Links 13 8...
Страница 482: ...Section 14 Troubleshooting Guide 14 20...
Страница 570: ...Appendix F Calibration and Zeroing F 16...
Страница 578: ...Appendix G Importing Files into Excel G 8...
Страница 579: ......