Description
Symbol
Unit
KMS02.1B-A018-P-D7-ET-NNN-NN-NN
Rise of voltage at output with U
LN_nenn
and
7.5 m motor cable length phase-ground
(10‑90%)
7)
dv/dt
kV/µs
5.00
Output frequency range when f
s
= 4 kHz
f
out_4k
Hz
0...400
Output frequency range when f
s
= 8 kHz
f
out_8k
Hz
0...800
Output frequency threshold to detect
motor standstill
8)
f
out_still
Hz
0...4
Maximum output current when f
s
= 4 kHz
I
out_max4
A
17.7
Maximum output current when f
s
= 8 kHz
I
out_max8
A
13.3
Continuous output current when
f
s
= 4 kHz
I
out_cont4
A
5.8
Continuous output current when
f
s
= 8 kHz
I
out_cont8
A
2.6
Continuous output current when
f
s
= 4 kHz; output frequency f
out
less
than f
out_still
I
out_cont0Hz_4
A
5.6
Continuous output current when
f
s
= 8 kHz; output frequency f
out
less
than f
out_still
I
out_cont0Hz_8
A
2.4
Latest amendment: 2018-02-22*
1)
Observe supply voltage for motor holding brake
2)
See information on "Rated power consumption control voltage
input at U
N3
"
3)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
4)
Also depending on firmware and control section; see parame‐
ter description "P‑0‑0001, Switching frequency of the power
output stage"; see "P-0-4058, Amplifier type data"; for supply
units the switching frequency is 4.2 kHz
5)
Plus dissipation of braking resistor and control section
6) 7)
Guide value, see following note
8)
See following note regarding output current reduction
9)
118 nF: L+ against ground; 100 nF: L- against ground
Tab. 5-7:
KMS - Technical data
Rated power consumption control voltage input at U
N3
Plus motor holding brake, plus power consumption of externally
connected inputs/outputs, plus safety option
Guide value "Rise of voltage at output"
Observe that the voltage load at the motor is almost independent
of the power section used.
Especially when using standard motors, make sure that they
comply with the occurring voltage load.
82/407
Technical data of the components
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04
Содержание Rexroth IndraDrive Mi KCU02
Страница 272: ...258 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 290: ...276 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 312: ...298 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 378: ...364 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 382: ...368 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 408: ...394 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 420: ...Notes 406 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 ...
Страница 421: ...Notes IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 407 407 ...