Device types with different drive power and interfaces are available for using
the Drive controllers in specific applications.
Typical applications include, for example:
●
Handling and mounting systems
●
Packaging and food machines
●
Printing and paper converting machines
●
Machine tools
Drive controllers may only be operated under the assembly and installation
conditions specified in this documentation, in the specified position of normal
use and under the specified ambient conditions (temperature, degree of
protection, humidity, EMC, etc.).
Note regarding the RoHS Directive 2011/65/EU:
The CSB01, CSH01 and CDB01 control sections do not meet the
requirements of the RoHS Directive 2011/65/EU.
However, the CSB01, CSH01 and CDB01 control sections may
still be placed on the market within the EU if they are exclusively
used in applications that are so-called "large-scale stationary
industrial tools" or so-called "large-scale fixed installations".
This is stated by the derogation contemplated by Article 2,
paragraph 4 of the RoHS Directive 2011/65/EU. Article 3 of this
Directive specifies the definitions.
2.2
Unintended use
"Unintended use" refers to using the Drive controllers outside of the operating
conditions, technical data and specifications described in this documentation.
Drive controllers must not be used, if …
●
they are exposed to operating conditions that do not meet the specified
ambient conditions. This includes, for example, operation under water,
under extreme temperature fluctuations or extreme maximum
temperatures.
●
Furthermore, Drive controllers may not be used in applications that have
not been expressly authorized by Rexroth. Therefore, please carefully
follow the specifications outlined in the general safety instructions!
Components of the IndraDrive Mi system are products of
Category C3 (with restricted distribution) in accordance with
IEC 61800‑3. This Category comprises EMC limit values for line-
based and radiated noise emission. Compliance with this
Category (limit values) requires the appropriate measures of
interference suppression to be used in the drive system (e.g.,
mains filters, shielding measures).
These components are not provided for use in a public low-
voltage mains supplying residential areas. If these components
are used in such a mains, high-frequency interference is to be
expected. This can require additional measures of interference
suppression.
34/407
Important directions for use
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04
Содержание Rexroth IndraDrive Mi KCU02
Страница 272: ...258 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 290: ...276 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 312: ...298 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 378: ...364 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 382: ...368 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 408: ...394 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 420: ...Notes 406 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 ...
Страница 421: ...Notes IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 407 407 ...