5.3
Function Group 2 [FU2]
51
5 - Parameter List
Code
[FU2]
Parameter Name
Setting Range
Factory
Default
Adj.
during
run
Page
H0
Jump Code
1-95
1
Yes
83
H1
Fault History 1
-
nOn
-
84
H2
Fault History 2
H3
Fault History 3
H4
Fault History 4
H5
Fault History 5
H6
Reset Fault History
0 (No)
1 (Yes)
0
(No)
Yes
84
H7
Dwell Frequency
0.1 - 400 [Hz]
5.00 [Hz]
No
84
H8
Dwell Time
0-10 [sec]
0.0 [sec]
No
84
H10
Skip Frequency Select
0 (No)
1 (Yes)
0 (No)
No
85
H11
1
Skip Frequency 1 Low
0.1 - 400 [Hz]
10.00 [Hz]
No
85
H12
Skip Frequency 1 High
15.00 [Hz]
H13
Skip Frequency 2 Low
20.00 [Hz]
H14
Skip Frequency 2 High
25.00 [Hz]
H15
Skip frequency low limit 3
30.00 [Hz]
H16
Skip frequency high limit 3
35.00 [Hz]
H17
S-Curve accel/decel start side
1~100 [%]
40
85
H18
S-Curve accel/decel end side
1~100 [%]
40
85
H19
Input/Output Phase Loss
Protection
0 (Disabled)
1 (Output phase
protection
2 (Input phase
protection)
3 (Input/Output
phase protection)
0
(Disabled)
Yes
86
H20
Power ON Start Select
0 (No)
1 (Yes)
0 (No)
Yes
87
H21
Restart after Fault Reset Select
0 (No)
1 (Yes)
0 (No)
Yes
87
H22
2
Speed Search Select
0000-1111 (bit
set)
Bit 0: during
Accel
Bit 1: after fault
reset
Bit 2: after instant
power failure
restart
Bit 3: when H20
is set to 1 (Yes)
0000
Yes
88
Содержание RSi GX Series
Страница 7: ...1 Introduction 1...
Страница 15: ...2 Technical Specifications 9...
Страница 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Страница 25: ...3 Receiving and Installation 19...
Страница 41: ...4 Operation 35...
Страница 53: ...5 Parameter List 47...
Страница 62: ...Notes 56 5 Parameter List...
Страница 63: ...6 Parameter Descriptions 57...
Страница 135: ...7 Remote Communication 129...
Страница 149: ...8 Troubleshooting Maintenance 143...
Страница 162: ...Notes 156 8 Troubleshooting Maintenance...
Страница 163: ...9 Options 157...
Страница 165: ...10 Appendices 159...