Ex 1) The drive determines the freq reference is lost when DRV- Frq is set
to 3 (Analog V1 input), I 16 to 1 and analog input signal is less than half the
value set in I 7.
Ex 2) The drive determines the freq reference is lost when DRV- Frq is set
to 6 (V1+I), I 16 to 2 and V1 input signal is either below the value set in I 7
or I input value is less than the I 12 value.
I17-I24: Multi-Function Input Terminals
Range:
0-24
Description:
The multi-function input terminals can be defined for many different
applications. The following table shows the various programmable
functions.
114
6 - Parameter Descriptions
Setting
Range
Description
Setting
Range
Description
Display
Display
0
Forward Run
13
-Reserved-
1
Reverse Run
14
-Reserved-
2
Stop Trip
15
Frequency (Up) Command
3
Reset [RST]
16
Frequency (Down)
Command
4
Jog Operation
17
3-wire operation
5
Step freq - Low
18
External trip: A (EtA)
6
Step freq - Mid
19
External trip: B (EtB)
7
Step freq - High
20
Self-diagnostic
8
Accel/Decel - Low
21
Exchange between PID
operation and V/F operation
9
Accel/Decel - Mid
22
Exchange between Option
and drive
10
Accel/Decel - High
23
Analog Hold
11
DC brake
24
Accel/Decel Disable
12
2nd motor
Code
Display
Default
Setting
I17
P1 define
0
See table below
I18
P2 define
1
I19
P3 define
2
I20
P4 define
3
I21
P5 define
4
I22
P6 define
5
I23
P7 define
6
I24
P8 define
7
Содержание RSi GX Series
Страница 7: ...1 Introduction 1...
Страница 15: ...2 Technical Specifications 9...
Страница 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Страница 25: ...3 Receiving and Installation 19...
Страница 41: ...4 Operation 35...
Страница 53: ...5 Parameter List 47...
Страница 62: ...Notes 56 5 Parameter List...
Страница 63: ...6 Parameter Descriptions 57...
Страница 135: ...7 Remote Communication 129...
Страница 149: ...8 Troubleshooting Maintenance 143...
Страница 162: ...Notes 156 8 Troubleshooting Maintenance...
Страница 163: ...9 Options 157...
Страница 165: ...10 Appendices 159...