Technical Data
2.1
Technical Data
1) Indicates the maximum applicable motor capacity when using a 4-pole motor.
2) Rated capacity is based on 220V for 200V class and 440V for 400V class.
3) Refer to when Carrier frequency setting (H39) is above 3kHz.
4) Max frequency setting range is extended to 300Hz when H40 (Control mode select) is
set to 3 (SVC).
5) Maximum output voltage cannot be higher than the input voltage. It can be
programmable below input voltage.
10
2 - TECHNICAL SPECIFICATIONS
Drive Type (RSixxxGX-2)
001
002
003
005
Motor
Rating
1
HP
1
2
3
5
KW
0.75
1.5
2.2
3.7
Output
Ratings
Capacity[kVA]
2
1.9
3.0
4.5
6.1
FLA [A]
3
5
8
12
16
Max. Frequency 400 [Hz]
4
Max. Voltage
3
f
200 - 230V
5
Input
Ratings
Rated Voltage
3
f
200 - 230 VAC (+10%, -15%)
Rated Frequency 50 - 60 [Hz] (
±
5%)
Cooling Method
Forced Cooling
Weight [kg]
0.77
1.12
1.84
1.89
230V Class (1.0 - 5.0HP)
Drive Type (RSixxxGX-4)
001
002
003
005
Motor
Rating
1
HP
1
2
3
5
KW
0.75
1.5
2.2
3.7
Output
Ratings
Capacity[kVA]
2
1.9
3.0
4.5
6.1
FLA [A]
3
2.5
4
6
8
Max. Frequency
400 [Hz]
4
Max. Voltage
3
f
380 - 480V
5
Input
Ratings
Rated Voltage
3
f
380 - 480 VAC (+10%, -15%)
Rated Frequency
50 - 60 [Hz] (
±
5%)
Cooling Method
Forced Cooling
Weight [kg]
0.77
1.12
1.84
1.89
400V Class (1.0 - 5.0HP)
Содержание RSi GX Series
Страница 7: ...1 Introduction 1...
Страница 15: ...2 Technical Specifications 9...
Страница 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Страница 25: ...3 Receiving and Installation 19...
Страница 41: ...4 Operation 35...
Страница 53: ...5 Parameter List 47...
Страница 62: ...Notes 56 5 Parameter List...
Страница 63: ...6 Parameter Descriptions 57...
Страница 135: ...7 Remote Communication 129...
Страница 149: ...8 Troubleshooting Maintenance 143...
Страница 162: ...Notes 156 8 Troubleshooting Maintenance...
Страница 163: ...9 Options 157...
Страница 165: ...10 Appendices 159...