Environmental Specifications
2.2
Environmental Specifiactions
Electrical Specifications
2.3
Electrical Specifications
12
2 - TECHNICAL SPECIFICATIONS
Protection degree
IP 20, NEMA TYPE 1 (Option)
Ambient temperature
-10°C to +50°C (non-freezing)
Storage temperature
-20°C to +65°C (-4°F to 149°F)
Humidity
0% to 95% RH (non-condensing)
Altitude
Max. 1,000m (3300ft) without derating
Maximum vibration
5.9 m/s
2
(19.2 ft/s
2
) [0.6G] or less
Cooling
Natural convection (1HP models)
Fan cooling (2HP and larger models)
Atmospheric pressure
70 to 106 kPa
Location
Protected from corrosive gas, combustible gas, oil
mist or dust
Table 1
200VAC Models
400VAC Models
Voltage input
3
f
200 - 230VAC -10%, -15% 3
f
380 - 10%, -15%
Line frequency
50 / 60Hz ±5%
DC bus voltage for:
Overvoltage trip
Dynamic Brake
activation
Nominal undervoltage
(UV) trip
407VDC
391VDC
202VDC
805VDC
780VDC
510VDC
Control system
Voltage Vector pulse width modulation (PWM)
Carrier frequency = 4, 6, 8, 12, and 16kHz
Output voltage
0 to 100% of line voltage, Three-phase
Overload capacity
150% of rated rms for 60 seconds
Rated output frequency 50/60Hz ±5%
Frequency range
0 to 1000Hz
Frequency stability
±0.02Hz from 0 to 300Hz (digital)
±0.01Hz from 300 to 1000Hz (digital)
0.1% (analog) over 24 hours ±10°C change
Frequency setting
Digital: keypad (0 to 10VDC, -10 to 10VDC, 0 to 20mA)
Agency listings
UL and cUL Listed, CE Mark
Table 2
Содержание RSi GX Series
Страница 7: ...1 Introduction 1...
Страница 15: ...2 Technical Specifications 9...
Страница 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Страница 25: ...3 Receiving and Installation 19...
Страница 41: ...4 Operation 35...
Страница 53: ...5 Parameter List 47...
Страница 62: ...Notes 56 5 Parameter List...
Страница 63: ...6 Parameter Descriptions 57...
Страница 135: ...7 Remote Communication 129...
Страница 149: ...8 Troubleshooting Maintenance 143...
Страница 162: ...Notes 156 8 Troubleshooting Maintenance...
Страница 163: ...9 Options 157...
Страница 165: ...10 Appendices 159...