To use this function:
•
Set H75 to 1.
•
Set %ED (Enable Duty) in H76.
H76: DB Resistor Operating Rate
Range:
0-30% (Default: 10)
Description:
Set the percent of DB resistor operating rate to be activated during one
sequence of operation.
To use this Function:
•
Set the resistor operating rate(%ED) in one sequence of operation.
Continuous usage reate is Max 15 sec and usage signal is not issued over
15 sec.
Example 1)
H
T dec
T acc
T dec
T stop
76
100
=
+
+
´
_
_
_
_
[%]
Where,
T_acc: Acceleration time to reach a setting freq.
T_steady: Time for constant speed operation at setting freq.
T_dec: Time to decelerate to lower freq. than that in constant speed.
or time to stop from freq. in constant speed.
T_stop: waiting time at a stop before operation is resumed.
104
6 - Parameter Descriptions
Freq.
T_acc T_steady
T_dec
T_stop
Take caution when DB resistor is used over its Watt
rating. Fire may result from resistor overheat. When using
a resistor with a thermal switch, program one of the
multi-function outputs to an external trip.
CAUTION
Содержание RSi GX Series
Страница 7: ...1 Introduction 1...
Страница 15: ...2 Technical Specifications 9...
Страница 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Страница 25: ...3 Receiving and Installation 19...
Страница 41: ...4 Operation 35...
Страница 53: ...5 Parameter List 47...
Страница 62: ...Notes 56 5 Parameter List...
Страница 63: ...6 Parameter Descriptions 57...
Страница 135: ...7 Remote Communication 129...
Страница 149: ...8 Troubleshooting Maintenance 143...
Страница 162: ...Notes 156 8 Troubleshooting Maintenance...
Страница 163: ...9 Options 157...
Страница 165: ...10 Appendices 159...