Braking Resistor
9.1
Short Circuit Fuse / Braking Resistor
Use class H or K5 UL Listed Input Fuse or a UL listed breaker only. See the table below
for the required voltage and current rating of fuses and breakers. Recommended suppliers
for input fuses are Bussman or Ferraz Shawmut.
158
9 - Options
Input Voltage
Motor [HP]
100% Braking
150% Braking
[
W
]
[W]*
[
W
]
[W]*
200V
Class
1.0
200
100
150
150
2.0
100
200
60
300
3.0
60
300
50
400
5.0
40
500
33
600
400V
Class
1.0
900
100
600
150
2.0
450
200
300
300
3.0
300
300
200
400
5.0
200
500
130
600
* The wattage is based on Enable duty (%ED) 5% with continuous braking time 15 sec.