R5905948 /12
Event Master Devices
191
4.
Select either add as a master or add as a slave.
Once the added S3
–
4K is done synchronizing with the system, the third (grayed-out) S3
–
4K will be available
to add to the system.
You will be presented the option to add the third S3
–
4K as a master or as a slave.
5.
Select either add as a master or add as a slave.
6.
(Optional) At this point it is suggested that you select and name appropriately each S3
–
4K so that you can
identify it in your setup.
How to Link an S3-4K Unit and an EX Unit with Two VPU Cards
To add up to eight Single or four Mixing Layers to a system, an S3-4K Unit can be linked to an EX Unit with two
VPU cards. This adds two additional VPUs to the system. Each S3
–
4K has a single Link card in slot 1,
identified by a yellow stripe at the top. Each EX has two Link sockets. Make sure to use the locking
mechanism and then push each cable until it locks in place.
Connect the Link cables provided with each unit between the Link connectors as follows:
•
S3 VP ID 0, Link Card slot 1, Link 1 >> EX VP ID 1, Link 2 [1]
•
S3 VP ID 0, Link Card slot 1, Link 2 >> EX VP ID 1, Link 1 [2]
See Image 6-56 for an example of the cabling between an S3-4K unit and an EX unit with two VPU cards.
Image 6-56: Cabling between an S3
–
4K unit and an EX unit with two VPN cards
When an EX unit has VPU cards rather than a combination of Input and Output cards, and it is
connected to an S3
–
4K processor, the EX unit an no longer be daisy-chained to another EX unit;
both Link connectors on the EX unit must be connected to the S3
–
4K Master unit.
How to Link an S3-4K Unit and an EX Unit with a Mixed I/O/VPU Configuration
To add up to four Single or two Mixing Layers to a system, an S3-4K Unit can be linked to an EX Unit with a
single VPU card. This adds another VPU to the system. The VPU can be in either slot 1 or slot 2 on the EX
unit, and the other slot may be empty or contain either an Event Master Input card or an Event Master Output
card. Each S3
–
4K has a single Link card in slot 1, identified by a yellow stripe at the top. Each EX has two Link
sockets. Make sure to use the locking mechanism and then push each cable until it locks in place.
Connect the Link cables provided with each unit between the Link connectors as follows:
•
S3 VP ID 0, Link Card slot 1, Link 1 >> EX VP ID 1, Link 2 [1]
•
S3 VP ID 0, Link Card slot 1, Link 2 >> EX VP ID 1, Link 1 [2]
See Image 6-57 for an example of the cabling between an S3-4K unit and an EX unit with two VPU cards.
Содержание Event Master E2 Series
Страница 1: ...ENABLING BRIGHT OUTCOMES User s Guide Event Master Devices...
Страница 12: ...R5905948 12 Event Master Devices 12...
Страница 24: ...R5905948 12 Event Master Devices 24 Safety...
Страница 52: ...R5905948 12 Event Master Devices 52 General...
Страница 82: ...R5905948 12 Event Master Devices 82 Hardware orientation...
Страница 102: ...R5905948 12 Event Master Devices 102 Front Panel Menu orientation...
Страница 272: ...R5905948 12 Event Master Devices 272 Image 6 137 EM GUI orientation...
Страница 304: ...R5905948 12 Event Master Devices 304 Updating firmware...
Страница 326: ...R5905948 12 Event Master Devices 326 Image 9 28 General operation example...
Страница 382: ...R5905948 12 Event Master Devices 382 Preventive maintenance actions...
Страница 386: ...R5905948 12 Event Master Devices 386 14 2 Process Overview Flow chart Image 14 2 E2 Maintenance...
Страница 444: ...R5905948 12 Event Master Devices 444 E2 Maintenance...
Страница 448: ...R5905948 12 Event Master Devices 448 15 2 Process Overview Flow chart Image 15 2 S3 Maintenance...
Страница 528: ...R5905948 12 Event Master Devices 528 EC 200 EC 210 Maintenance...
Страница 569: ...569 R5905948 12 Event Master Devices Troubleshooting C...
Страница 572: ...R5905948 12 Event Master Devices 572 Troubleshooting...
Страница 583: ...R5905948 12 Event Master Devices 583 Index...