R5905948 /12
Event Master Devices
185
Image 6-50: Cabling between an E2 unit and two EX units
When an EX unit has VPU cards rather than a combination of Input and Output cards, and it is
connected to an E2 processor or to an S3
–
4K processor, the EX unit an no longer be daisy-chained
to another EX unit; both Link connectors on the EX unit must be connected to the E2 or S3
–
4K
Master unit.
How to Link an E2 Unit to Two EX Units, Each with a Mixed I/O/VPU Configuration
To add up to eight Single Layers or four Mixing Layers to a system, an E2 unit can be linked to two EX units,
each with a single VPU card. This adds two VPUs. The VPU can be in either slot 1 or slot 2 on the EX unit,
and the other slot may contain either an Event Master Input card or an Event Master Output card. Each E2
comes equipped with two Link cards, always located in slots 1 and 2. Link cards are identified by a yellow
stripe at the top. Each EX has two Link sockets. Make sure to use the locking mechanism and then push each
cable until it locks in place.
To link an E2 to two EX units, connect the Link cables provided with each unit between the Link connectors as
follows:
•
E2 VP ID 0, Link Card slot 1, Link 1 >> EX VP ID 1, Link 2 [1]
•
E2 VP ID 0, Link Card slot 1, Link 2 >> EX VP ID 1, Link 1 [2]
•
E2 VP ID 0, Link Card slot 2, Link 1 >> EX VP ID 2, Link 2 [3]
•
E2 VP ID 0, Link Card slot 2, Link 2 >> EX VP ID 2, Link 1 [4]
See Image 6-51 for an example of the cabling between an E2 unit and an EX unit with a VPU card and either
an Event Master Input card or an Event Master Output card.
Содержание Event Master E2 Series
Страница 1: ...ENABLING BRIGHT OUTCOMES User s Guide Event Master Devices...
Страница 12: ...R5905948 12 Event Master Devices 12...
Страница 24: ...R5905948 12 Event Master Devices 24 Safety...
Страница 52: ...R5905948 12 Event Master Devices 52 General...
Страница 82: ...R5905948 12 Event Master Devices 82 Hardware orientation...
Страница 102: ...R5905948 12 Event Master Devices 102 Front Panel Menu orientation...
Страница 272: ...R5905948 12 Event Master Devices 272 Image 6 137 EM GUI orientation...
Страница 304: ...R5905948 12 Event Master Devices 304 Updating firmware...
Страница 326: ...R5905948 12 Event Master Devices 326 Image 9 28 General operation example...
Страница 382: ...R5905948 12 Event Master Devices 382 Preventive maintenance actions...
Страница 386: ...R5905948 12 Event Master Devices 386 14 2 Process Overview Flow chart Image 14 2 E2 Maintenance...
Страница 444: ...R5905948 12 Event Master Devices 444 E2 Maintenance...
Страница 448: ...R5905948 12 Event Master Devices 448 15 2 Process Overview Flow chart Image 15 2 S3 Maintenance...
Страница 528: ...R5905948 12 Event Master Devices 528 EC 200 EC 210 Maintenance...
Страница 569: ...569 R5905948 12 Event Master Devices Troubleshooting C...
Страница 572: ...R5905948 12 Event Master Devices 572 Troubleshooting...
Страница 583: ...R5905948 12 Event Master Devices 583 Index...