Monitor and RTC Description 12-3
MN766
P#
Type
Name
Unit
Help
55
ACC/DEC DEMAND
Hz/SEC
Accel/Decel Demand. - Current ramp rate used by the velocity profi ler
56
ID CURRENT
A
ID Current. - D axis measured current proportional to motor fl ux
57
ID DEMAND
A
ID Demand. - D axis demand current proportional to motor fl ux
58
IQ CURRENT
A
IQ Current. - Q axis measured current proportional to motor torque
59
IQ DEMAND
A
IQ Demand. - Q demand current proportional to motor torque
60
POWER FACTOR
Power Factor. - Ratio of (real power)/(apparent power)
61
PHASE 1 CURRENT
A
Phase 1(U) Current. - Phase U current
62
PHASE 2 CURRENT
A
Phase 2(V) Current. - Phase V current
63
PHASE 3 CURRENT
A
Phase 3(W) Current. - Phase W current
64
VD DEMAND
V
VD Demand. - D axis voltage demand for setting up motor fl ux
65
VQ DEMAND
V
VQ Demand. - Q axis voltage demand for setting up motor torque
66
ELECTRICAL ANGLE
°
Electrical Angle. - Electrical angle used to develop phased voltages to
the motor
67
MOTOR SPEED
RPM
Motor Speed. - Current speed of the motor
68
AT TEST DESC
Autotune Test Description. - Description of current autotuning state
69
R/W
APP LAYER ERROR
Application Layer Error. Application layer error code number. The last
error that occurred
70
USB TRANSACTIONS
USB Transactions. Total number of USB transactions since start up
71
USB ERRORS
USB Errors. Total number of USB errors since start up
72
TSK STATUS
Task Status. Runtime task overrun status. Bits correspond to tasks that
have overrun their time limit
73
TSK ID
Task ID. First task that overran its time slot
74
TSK COUNT
Task Count. Total number of overruns for the fi rst task to overrun its time
slot
75
Kp PACKETS
Keypad Packets. Total number of processed keypad packets
76
Kp T-GAPS
Keypad Gaps. Total number of keypad inter-packet time gap errors
77
Kp NAKs
Keypad NAKs. Total number of NAKs sent. High word are received
NAKs low word is transmitted NAKs
78
EST POWER
kW
Estimated Power. - Drive power output estimated from measured current
and voltages. Units: KW
79
EST ENERGY
kWH
Estimated Energy. - Delivered by drive. Estimated from measured
current and voltages. Units: kHW
80
EST COST
$
Estimated Cost. - Cost of output energy delivered. Estimated from cost
of kWH unit parameter
81
R/W ACCESS
KEY
Access Key. - Parameter security access key. Contact Baldor to decode
the key code
82
R/W
KEYPAD SOFT VER
Keypad Software Version. - Keypad software version string
Table 12-1 Monitor Parameters Descriptions Continued
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...