9-6 Troubleshooting
MN766
9.2 Diagnostic Information
After power up, select the Diagnostic Menu to see information from the diagnostic displays.
Action
Description
Display
Comments
Press Menu
Displays top level menu options.
STATUS
BASIC PARAMS
ADVANCED PROG
EVENT LOG
DIAGNOSTICS
STATUS
BACK
Press
or
to move cursor over
the “DIAGNOSTICS” selection.
Press
to display next
group.
Displays active operating mode
settings.
STATUS
0r
MAIN
OPERATING MODE
Keypad
Speed
AC Servo
DIAG
LOCAL
Press
to display next
group.
Bit display of digital inputs,
outputs and the voltage present at
the internal 24V supply terminals.
STATUS
0r
MAIN
DIGITAL I/O
INPUTS
100000000
OUTPUTS
0001
USER 24V
24.9V
DIAG
LOCAL
Press
or
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press
to display next
group.
Output Frequency, % Feedforward
% Setpoint, % Feedback
STATUS
0r
MAIN
PROC CONTROL PID
0.00HZ
0.0FF
0.0SP
0.0FB
DIAG
LOCAL
Press
or
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Note: This screen does not appear
unless P1401 is set to
Diagnostic Display
Displays software version, hp,
volts and Amp/Volt ratings.
STATUS
0r
MAIN
SHH-1.21
RATED HP
3HP
RATED VOLTS
240.0V
RATED A/V
4.0A/V
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
or
Note: Example display shows that
the drive enable terminal
(J2-8) is on and that
Relay Out 2 is on.
STOP
STOP
STOP
Press
to display next
group.
STATUS
0r
MAIN
SHH-1.21
RATED CURRENT
9.6A
RATED PK CU
16.8A
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press
to display next
group.
Displays:
Power Base ID number
EE Firmware version
FPGA firmware version
STATUS
0r
MAIN
POWER BASE VERSION
ID
0x000A2003
EE VER
0x00000001
FPGA VER
0x00000A02
DIAG
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
0x=Hexadecimal
0b=Binary
Press
to display next
group.
Displays real time clock values
(date and time) and total run time
since installation.
Press ENTER to set date and
time.
STATUS
0r
MAIN
REAL TIME CLOCK
Jan 1, 2009
22:07:35
RUN TIMER
474.1HR
DIAG
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
or
or
or
STOP
STOP
Press Enter to view diagnostic
information.
Process Control.
Press F2 to return to main menu.
Press F1 to return to STATUS screen.
Press F1 to return to STATUS screen.
Press F1 to return to STATUS screen.
Press F1 to return to STATUS screen.
Press F1 to return to STATUS screen.
Press F1 to return to STATUS screen.
Press F1 to return to STATUS screen.
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...