7-2 Parameter Descriptions
MN766
Block Title
Parameter (Number)
Selection (Value)
Parameter Name and Description
RAMP
RATES
(Continued)
PL DEC TIME
(1113)
Preset Value: 1.0
Range: 0.0 to 3600.0 Seconds
Time to stop the motor from maximum drive speed during a power loss.
% Maximum Speed
100
80
60
40
20
-20
-40
0
Accel Time
Start
S-Accel 1
End
S-Accel 1
Decel Time
Start
S-Decel 1
End
S-Decel 1
Speed Curve
(Accel)
Speed Curve
(Decel)
Seconds
2
4
6
8
10
Commanded Speed
12
Decel Rate
Accel Rate
JOG
SETTINGS
JOG SPEED
(1201)
Preset Value: 210
Range: 0 - MAX Speed RPM
Jog Speed is the programmed speed used during jog. Jog can be initiated
from the keypad or terminal strip. At the Keypad, press and release the
JOG key then press and hold the direction (FWD or REV). For Standard Run
3Wire mode, close the JOG input (J2-12) at the terminal strip then close and
maintain the direction input (J2-9 or J2-10). Process Control mode operation
is different. If the terminal strip Process Control Enable input (J2-13) is
closed, pressing the Keypad JOG key (or closing J2-14) will cause the drive
to move in the direction of the error (without pressing FWD or REV).
JOG ACCEL TIME
(1202)
Preset Value: 10.0
Range: 0.0 to 3600.0 Seconds
The accel rate or time to reach max Speed.
Time to reach Jog Speed=(Jog Speed/Max Speed) x (Jog Accel Time).
JOG START S-ACC
(1203)
Preset Value: 0.0
Range: 0.0 to 100.0%
Start S-Curve Acceleration as a percentage of jog accel time.
JOG END S-ACC
(1204 )
Preset Value: 0.0
Range: 0.0 to 100.0%
End S-Curve Acceleration as a percentage of jog accel time.
JOG DECEL TIME
(1205)
Preset Value: 10.0
Range: 0.0 to 3600.0 Seconds
The decel rate or time to decel from max Speed.
Time to reach zero speed=(Jog Speed/Max Speed) x (Jog Decel Time).
JOG START S-DEC
(1206)
Preset Value: 0.0
Range: 0.0 to 100.0%
Start S-Curve Deceleration as a percentage of jog decel time.
JOG END S-DEC
(1207)
Preset Value: 0.0
Range: 0.0 to 100.0%
End S-Curve Deceleration as a percentage of jog decel time.
JOG FORWARD
(1209)
Preset Value: 1
Range: 0 - 1
Off (0)
Mode Disabled.
On (1)
Enables Jog in the drive forward direction at Jog speed for keypad mode.
JOG REVERSE
(1210)
Preset Value: 1
Range: 0 - 1
Off (0)
Mode Disabled.
On (1)
Enables Jog in the drive reverse direction at Jog speed for keypad mode.
Table 7-1 Level 1 Parameter Block Defi nitions Continued
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...