Parameter Tables B-13
MN766
Block Title
Parameter
P#
Adjustable Range
Factory
User Setting
PULSE
FOLLOWER
(Continued)
RX RATIO OUT 2
3108
1 - 1048576
1024
RX RATIO OUT 3
3109
1 - 1048576
1024
RX RATIO OUT 4
3110
1 - 1048576
1024
OUTPUT TYPE
3111
0-Quadrature
1-Speed
0
TX RATIO INPUT
3112
1 - 1048576
1024
TX RATIO OUTPUT
3113
1 - 1048576
1024
SAVE RX OUT RATIO
3114
0 - 1
0
CUSTOM
UNITS
MAX DEC PLACES
3201
0 - 5
1
VALUE AT SPEED
3202
0.0 - 9999999.0 (X.X: YRPM)
0.0: 0RPM
UNITS OF MEASURE
3203
ASCII & Graphic Characters
Cust
PRESET
POSITIONS [2]
PRESET REVs 2
3301
(-49999 to 49999) : (-4095 to 4095)
1:0000
PRESET REVs 3
3302
(-49999 to 49999) : (-4095 to 4095)
2:0000
PRESET REVs 4
3303
(-49999 to 49999) : (-4095 to 4095)
3:0000
PRESET REVs 5
3304
(-49999 to 49999) : (-4095 to 4095)
4:0000
PRESET REVs 6
3305
(-49999 to 49999) : (-4095 to 4095)
5:0000
PRESET REVs 7
3306
(-49999 to 49999) : (-4095 to 4095)
6:0000
PRESET REVs 8
3307
(-49999 to 49999) : (-4095 to 4095)
7:0000
PRESET REVs 9
3308
(-49999 to 49999) : (-4095 to 4095)
8:0000
PRESET REVs 10
3309
(-49999 to 49999) : (-4095 to 4095)
9:0000
PRESET REVs 11
3310
(-49999 to 49999) : (-4095 to 4095)
10:0000
PRESET REVs 12
3311
(-49999 to 49999) : (-4095 to 4095)
11:0000
PRESET REVs 13
3312
(-49999 to 49999) : (-4095 to 4095)
12:0000
PRESET REVs 14
3313
(-49999 to 49999) : (-4095 to 4095)
13:0000
PRESET REVs 15
3314
(-49999 to 49999) : (-4095 to 4095)
14:0000
POS PROP GAIN
3329
000.0000 to 100.0000
000.1000
POS INTG GAIN
3330
000.0000 to 100.0000
000.0000
POS INTG CLAMP
3331
000.0 to 100.0%
10.0
POS DIFF GAIN
3332
000.0000 to 100.0000
0.0000
POS MAX ADJUST
3333
000.0 to 100.0%
10.0
POS FILTER
3334
0.1 to 500.0Hz
10.0
[2] The adjustable range of each Preset Position parameter is x:y where:
x= -49999 to 49999 REV
y= -4095 to 4095 counts
Note: In Mint WorkBench, each position is displayed as individual parameters.
For example, Preset POS 2 is 3301 (X) and 3315 (y). Parameters 3315 through 3328 are viewable only in Mint
WorkBench.
PLC MODE
PLC CONFIG 1
3401
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 2
3402
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 3
3403
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 4
3404
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 5
3405
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 6
3406
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 7
3407
0 to 255.255.255.255
000.128.000.000
PLC CONFIG 8
3408
0 to 255.255.255.255
000.128.000.000
Table B-3 Parameter Block Values Level 3 (Cont.)
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...