6-12 Using the Keypad
MN766
Change a parameter value within the linear list as follows:
Action
Description
Display
Comments
Press Enter to select
the parameter value to
be viewed or modified.
The number and name of each
parameter is displayed in listing
format.
PNUM
BACK
C1001 PRESET SPEED 1
F1002 PRESET SPEED 2
F1003 PRESET SPEED 3
F1004 PRESET SPEED 4
F1005 PRESET SPEED 5
Press
or
keys to scroll to
through the parameter list.
Press
or
keys to jump to
next page.
Press F2 to return to previous
menu.
Press Enter to change
the parameter value.
The parameter value can be
changed as previously described
in Advanced Programming.
PROG
PRESET SPEED 1
38 RPM
C1001T1
STATUS
BACK
PRESET SPEEDS
Press Enter then use cursor keys
to position cursor and increase or
decrease each character under
the cursor as desired.
Press F2 to return to previous
menu.
Jump to display a different range of parameters as follows:
Press F1 key (PNUM)
to highlight Parameter
Number.
The parameter number is
highlighted.
PNUM
BACK
Press F1 key (PNUM) to highlight
Parameter Number
.
Press
or
keys to scroll.
Press F2 (BACK) to return to
previous menu.
Press Enter key to edit
the highlight Parameter
Number.
The parameter number is
highlighted.
PNUM
BACK
C2001 PRESET SPEED 1
F1002 PRESET SPEED 2
F1003 PRESET SPEED 3
F1004 PRESET SPEED 4
F1005 PRESET SPEED 5
Use cursor keys to position cursor
and increase or decrease each
character under the cursor as
desired. Press Enter when
finished.
Press F2 to return to previous
menu.
The newly selected parameter
number range is displayed.
These values may be viewed and
changed or jump to a different
parameter range may be
performed.
PNUM
BACK
F2001
F2002 MIN OUTPUT SPEED
F2003 MAX OUTPUT SPEED
F2004 PWM FREQUENCY
F2006 CURR RATE LIMIT
Press or
keys to scroll to
through the parameter list.
Press
or
keys to jump to
next page. Press F2 (BACK) to
return to previous menu.
C1001 PRESET SPEED 1
F1002 PRESET SPEED 2
F1003 PRESET SPEED 3
F1004 PRESET SPEED 4
F1005 PRESET SPEED 5
OPERATING ZONE
Action
Description
Display
Comments
6.8 Event Log
From the Menu display screen, select Event Log and press enter. Trace is used to display control conditions present at the
time the fault occurred. A separate trace log is recorded for each event.
Action
Description
Display
Comments
Event Log Display
LOW INITIAL BUS
0
Date
Time
Entry #
0-9
HH:MM:SS
Displays error name,
Entry # and time the
error occurred.
DD/MM/YY
EV. LOG
STATUS
TRACE
LOW INITIAL BUS
0
4-Jul-06
09:35:00
LOCAL
STOP
Press
or to view next entry.
Press F2 to view Trace Log
Press F1 to return to Status
Menu.
Note: Trace is described in
Chapter 9 of this manual.
Input states, Output states, various voltage and current values etc. can be viewed to help understand the cause of the fault
condition. See Chapter 9 of this manual for more information.
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...