10-6 PLC Mode Description
MN766
ID
Description
28
Preset Speed Select Table Index Bit 3 - If the input condition is True then bit 3 of the Preset Speed Select Table Index
is set else it is reset. NOTE: If this action is not programmed then bit 3 is reset.
29
Process PID Enable/Disable - If the input condition is True then the Process PID is active otherwise it is inactive.
NOTE: The Process PID is automatically set to inactive during keypad control or while jogging.
30
Keypad - If the input condition is True then forward/reverse and stop commands along with the keypad's local speed
reference control the drive. The keypad is disabled by default.
31
Electronic Pot - If the input condition is True the Electronic Pot sets the speed reference otherwise it is not active. The
pot is disabled by default.
32
Decrease Electronic Pot Speed Reference- If the input condition is True the Electronic Pot speed reference is
increased else has no affect. NOTE: E-Pot is non-volatile. NOTE: E-Pot is unipolar so direction is determined by
forward/reverse commands.
33
Increase Electronic Pot Speed Reference- If the input condition is True the Electronic Pot speed reference is
decreased else has no affect. NOTE: E-Pot is non-volatile. NOTE: E-Pot is unipolar so direction is determined by
forward/reverse commands.
34
Parameter Table Select Enable - If the input condition is True enables parameter table selection through the
parameter table select index, else parameter table selection is disabled.
35
Parameter Table Select Index Bit 0 - If the input condition is True then bit 0 of the Parameter Table Select Index
is set else it is reset. NOTE: If this action is not programmed then bit 0 is reset. NOTE: This index sets the active
parameter table
36
Parameter Table Select Index Bit 1 - If the input condition is True then bit 1 of the Parameter Table Select Index
is set else it is reset. NOTE: If this action is not programmed then bit 1 is reset. NOTE: This index sets the active
parameter table
37
Relay Output 2 - If the input condition is True then Relay Output 2 (J3-28,29,30) will be active otherwise it is inactive
NOTE: Relay Output 2 must have been set to “PLC” using P1504
38
Torque/Speed Mode - If the input condition is True then the drive controls torque else it controls speed. Default is
speed control. NOTE: For V/F, torque control is not supported and is ignored.
39
Seed E-Pot - If the condition is true, the current speed reference is seeded into the E-Pot speed reference.
Otherwise, it is not seeded. NOTE: E-Pot must not be the active speed reference for seeding to occur.
40
Logical Variable A - If the input condition is True then logical variable A is set else reset
41
Logical Variable B - If the input condition is True then logical variable B is set else reset
42
Logical Variable C - If the input condition is True then logical variable C is set else reset
43
Logical Variable D - If the input condition is True then logical variable D is set else reset
44
Logical Variable E - If the input condition is True then logical variable E is set else reset
45
Logical Variable F - If the input condition is True then logical variable F is set else reset
46
Logical Variable G - If the input condition is True then logical variable G is set else reset
47
Logical Variable H - If the input condition is True then logical variable H is set else reset
48
Logical Variable I - If the input condition is True then logical variable I is set else reset
49
Logical Variable J - If the input condition is True then logical variable J is set else reset.
50
Start Timer A - If the input condition is True zero Timer A else count up to a timeout.
51
Stop Timer A - If the input condition is True, set Timer A= P3440 counts else do nothing.
52
Start Timer B - If the input condition is True, set Timer B= 0 else count up to a timeout.
53
Stop Timer B - If the input condition is True, set Timer B= P3441 counts else do nothing.
54
Start Timer C - If the input condition is True, set Timer C= 0 else count up to a timeout.
55
Stop Timer C - If the input condition is True, set Timer C= P3442 counts else do nothing.
56
Start Timer D - If the input condition is True, set Timer D= 0 else count up to a timeout.
57
Stop Timer C - If the input condition is True, set Timer D= P3443 counts else do nothing.
58
Pulse Start Timer A –If the input condition is True and timer A has expired then restarts timer A
59
Pulse Start Timer B –If the input condition is True and timer B has expired then restarts timer B
60
Pulse Start Timer C –If the input condition is True and timer C has expired then restarts timer C
Table 10-3 PLC Actions Continued
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...