Parameter Tables B-7
MN766
Block Title
Parameter
P#
Adjustable Range
Factory
User Setting
COMMUNI-
CATION
BAUD RATE
1701
0-9600
1-19200
2-38400
3-56000
4-115200
1
PARITY
1702
0-None
1-Odd
2-Even
0
STOP BITS
1703
0-One
1-Two
0
DRIVE ADDRESS
1704
1 - 247
1
OPT CARD RESET
1705
0-Off
1-Slot 1
2-Slot 2
3-Slots 1 & 2
0
SECURITY DEFAULT
1706
0-No
1-Yes
0
BROWSER USER ID
1707
ASCII user ID for the Ethernet Web
Browser Option Board if installed.
baldor
BROWSER PASSWORD
1709
Password for the Ethernet Web Browser
Option Board if installed.
baldor
CUSTOM
MOTOR
ALIGNMENT CURRENT
1821
10.0 to 100.0%
50.00%
ALIGNMENT TIME
1822
0.0 to 60.0 seconds
5.0