B-10 Parameter Tables
MN766
Block Title
Parameter
P#
Adjustable Range
Factory
User Setting
MOTOR DATA
(Continued)
ENCODER TYPE
2410
0-Single
1-Differential
Use default
setting
only
RESOLVER SPEED
2411
0 - 10
1
MOTOR POLE PAIRS
2413
1 - 100
2
CALC MOTOR MODEL
2414
0-No
1-Yes
0
REVERSE ROTATION
2415
0-Off
1-On
0
BRAKE ADJUST
RESISTOR OHMS
2501
0 - 255.0Ohms
CALC
RESISTOR WATTS
2502
0 - 999999Watts
CALC
RESISTOR TTC
2503
20 - 3600 seconds
CALC
PROCESS
CONTROL
PROCESS TYPE
2601
0-None
1-Forward Acting
2-Reverse Acting
0
SETPOINT ADJ LIM
2602
0.0 - 100.0%
100.0%
PROC FEEDBACK
2603
0-None
1-Setpoint Cmd
2-Local Speed Ref
3-Analog In1
4-Analog In2
5-Network
6-Composite Ref
7-Opt1 Ana In1
8-Opt1 Ana In2
9-Opt2 Ana In1
10-Opt2 Ana In2
0
SETPOINT SOURCE
2604
0-None
1-Setpoint Cmd
2-Local Speed Ref
3-Analog In1
4-Analog In2
5-Network
6-Composite Ref
7-Opt1 Ana In1
8-Opt1 Ana In2
9-Opt2 Ana In1
10-Opt2 Ana In2
0
SETPOINT COMMAND
2605
-100.0% to +100.0%
0.0
PROC ERR TOL
2606
0.0 - 100.0%
10.0
PROC PROP GAIN
2607
0.0000 - 1000.0000
1.0000
PROC INTG GAIN
2608
0.0000 - 1000.0000
0.0000
PROC INTG CLAMP
2609
0.0 - 100.0%
100.0
PROC DIFF GAIN
2610
0.0000 - 1000.0000
0.0000
PROFILE ADJUST
2611
0-Off
1-On
0
PROFILE ADJ BAND
2612
0.0 - 200.0%
50.0
PROC SLEEP BAND
2613
0.0 - 100.0%
0.0
PROC OUT FILTER
2614
0.0 - 100.0 seconds
0.00
PROC OUT OFFSET
2615
-100.0 - 100.0%
0.0
PROC OUT GAIN
2616
0.0 - 200.0%
100.0
Table B-2 Parameter Block Values Level 2 (Cont.)
Содержание VS1SD
Страница 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Страница 12: ...2 2 General Information MN766...
Страница 16: ...3 4 Installing the Drive MN766...
Страница 108: ...7 34 Parameter Descriptions MN766...
Страница 114: ...8 6 Customizing Your Application MN766...
Страница 128: ...9 14 Troubleshooting MN766...
Страница 154: ...12 12 Monitor and RTC Description MN766...
Страница 188: ...E 2 Remote Keypad Mounting Template MN766...