Avaya Communication Manager controlled maintenance
MG-DS1 (DS1 Interface Media Module)
Maintenance of the Avaya G350 Media Gateway
189
June 2004
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
MG-DS1 detects a Loss of Signal alarm. The physical link is broken or the
remote DS1 endpoint is down. All trunks or ports of this MM710 are out-of-
service. If the MG-DS1 connects to a T1 network facility:
If the MM710 connects to a T1 facility, call the vendor of the T1 carrier to
diagnose the remote DS1 endpoint. If the MM710 Interface Media Module
connects directly to a switch, call the system technician of the remote switch to
diagnose the DS1 endpoint.
If the MG-DS1 connects to a line-side terminating device such as a PRI
terminal adapter: Contact the vendor of the line-side terminating device to
diagnose the equipment.
Check the physical connection of the MM710 Interface Media Module and the
cable.
Check the physical connection of the MM710 Interface Media Module to the
terminating device. Check premise distribution system (or intra-premise
wiring) for physical connection failures.
1400
FAIL
Echo Canceller Function failed, this could be a hardware problem on the
MM710:
Use the
busyout board
command.
Use the
test board long
command.
Use the
release board
command.
If Test 1420 still fails, replace the board.
1401
FAIL
Echo Canceller Function failed, this could be a hardware problem on the
MM710:
Use the
busyout board
command.
Use the
reset board
command.
Use the
test board long
command.
Use the
release busy board
command.
If the test still fails replace the board.
PASS
DS1 signal is present and the physical link is healthy.
Table 109: TEST #138 Loss of Signal Alarm Inquiry Test 2 of 3
Error
Code
Test
Result
Description/ Recommendation
2 of 3
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...