Avaya Communication Manager controlled maintenance
CO-TRK (Analog CO Trunk)
100
Maintenance of the Avaya G350 Media Gateway
June 2004
1018
ABORT
Test has been disabled via administration.
1
Verify that the "Maintenance Tests?" field on the Trunk
Group Form is set to "n." To enable the test, use the change
trunk-group x command where "x" equals the number of
the trunk group to be tested. Then change the entry in the
"Maintenance Tests?" field on the form to "y."
2000
ABORT
Response to the test was not received within the allowable time
period.
1
Retry the command at 1-minute intervals for a maximum of
5 times.
FAIL
Trunk was seized, but dial tone could not be detected.
1
Test all administered outgoing ports on the board. Failure of
1 indicates a problem toward the CO.
2
If all fail, see note below.
3
Check for errors on the TONE-BD or TONE-PT. Clear any
errors found, and repeat the test.
4
If the error has still not cleared, refer the problem to the CO.
5
If no service problems exist on the port, continue to use the
port until the circuit pack can be replaced (as a last resort).
Perform a trunk test call to see if the trunk is operable.
NOTE:
If the dial tone test fails for all ports on a circuit pack,
a -5 volt power problem is indicated. To investigate
problems with a power unit, refer to “CARR-POW”.
2002
FAIL
Seizure portion of test failed due to hardware problem. Fault is
usually caused by a disconnected trunk.
1
If the CO Demand Diagnostic Test (#3) also failed, display
the Hardware Error Log. If the CO Demand Diagnostic Test
failed because it could not detect ground (indicated by Error
Type 1281 in the Hardware Error Log) AND Error Type
3329 or 3585 appears in the Hardware Error Log (with the
same last occurred time as Error Type 1281 and 1537),
replace the circuit pack.
2
Check trunk wiring to ensure good connection; repeat test if
wiring correction made.
3
Locate another identical CO trunk and swap its wiring with
one under test. Repeat test on both trunks and determine if
problem follows trunk or remains at original port. If problem
follows trunk, refer problem to CO. If problem remains at
port, replace circuit pack and repeat test.
Table 49: Test #0 Dial Tone Test 2 of 3
Error
Code
Test
Result
Description/ Recommendation
2 of 3
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...