Avaya Communication Manager controlled maintenance
DID-TRK (Direct Inward Dial Trunk)
Maintenance of the Avaya G350 Media Gateway
115
June 2004
61446
FAIL
Battery feed test failed. A loop current fault was detected. This is most
probably an incoming CO-line problem. This failure code is only reported
by the TN2139 Italian DID Media Module.
Check the incoming CO-line for loop current. If none is detected refer the
problem to the CO.
If the CO-line checks out OK, the failure must be on the DID port. Replace
the Media Module.
61456
FAIL
Battery feed test failed. An on-board problem was detected. This port is out-
of-service.
Replace Media Module.
61472
FAIL
Battery feed test failed. A problem with the incoming CO-line was detected.
Check the incoming CO-line for proper operation. If warranted, refer the
problem to the CO.
If the CO-line is not at fault, the failure must be on the DID port. Replace
the Media Module.
PASS
Current flow was detected for this port.
User-reported troubles on this port should be investigated using other port
tests and by examining connections.
Refer problem to the CO.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board).
Check to ensure that the board translations are correct. Translate the board,
if necessary.
Use the
busyout board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board
command. This should re-establish the linkage
between the internal ID and the port.
If the problem persists, replace the circuit pack.
Table 59: TEST #35 Port Diagnostic Test 2 of 2
Error
Code
Test
Result
Description/ Recommendation
2 of 2
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...