Alarming
Alarm management
Maintenance of the Avaya G350 Media Gateway
291
June 2004
The command syntax is:
snmp-server host {<hostaddress>|<hostname>} {traps|informs} {{{v1|v2c} <community> |
{v3 [auth|noauth|priv] <user>}} [udp-port <port>] [<notification-type-list>]
This command is used both to specify the destination host for SNMP messages, and to define which
SNMP messages are to be sent.
For example, to enable the SNMPv3 manager at IP address 192.16.55.126 to receive inform-type
messages, to use SNMPv3 authentication, and to receive Ethernet port fault notifications only, enter:
G350-001(super)# snmp-server host 192.16.55.126 informs v3 auth
localuser eth-port-faults
NOTE:
You must log in to the CLI as
admin
to administer SNMP settings.
Refer to
Table 156, SNMPv3 Notification Types,
on page 291 for a full list of notification types that can
be configured.
Configure SNMPv3 authentication
In order to use SNMPv3 authentication, you must create users, groups, and views for the G350.
The G350 provides several pre-configured views and groups for setting up SNMP authentication. Refer
to
Table 157, G350 Pre-configured Views,
Table 158, G350 Pre-configured Groups,
page 292 for a description of these objects and how they can be used.
Table 156: SNMPv3 Notification Types
Notification Type
Description
all
All notifications
generic
Generic traps
config
Configuration change notifications
eth-port-faults
Ethernet port fault notifications
sw-redundancy
Software redundancy notifications
temperature
Temperature warning notifications
cam-change
Changes in CAM notifications
l3-faults
L3 level faults (e.g., duplicate IP, VLAN violations)
lag-event
Link aggregation faults and configuration changes
policy
Changes in policy (L3 devices) notifications
link-down-faults
Link down notifications
supply
Power supply (main and backup) notifications
fan
FAN faults (main and backup) notifications
cascade
Cascade connection fault notifications
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...