Media Server alarms
S8300 alarms – _WD
Maintenance of the Avaya G350 Media Gateway
311
June 2004
S8300 alarms – _WD
See
on page 311 through
on page 315 for a list of S8300
Alarms – _WD.
Table 163: Alarm #8
Number
8
Source
_WD
Event ID
4
Alarm Level
Major
Alarm Text Description
Maximum retries for app start
Possible Causes
Application failed (cannot start) maximum allowed number of
times. The application is present but not launching.
Determining Cause
Go to the Web Interface; choose Diagnostics; View System Logs;
select Watchdog Logs
Resolution
1. On the Web Interface, choose View Process Status and select
the appropriate settings
2. From the Web Interface, choose Alarms and Notification; select
the appropriate alarm; choose Clear
Table 164: Alarm #9
Number
9
Source
_WD
Event ID
6
Alarm Level
Major
Alarm Text Description
Cannot open config parameter file
Possible Causes
Watchdog cannot read its configuration file
/etc/opt/ecs/watchd.conf
Determining Cause
Go to the Web Interface; choose Diagnostics; View System Logs;
select Watchdog Logs
Resolution
1. Get a fresh copy of watchd.conf (from the CD for field, and
from remote server or /root2 for the labs).
2. From the Web Interface, choose Alarms and Notification; select
the appropriate alarm; choose Clear
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...