Avaya Communication Manager controlled maintenance
MG-BRI (BRI Trunk Media Module MM720 and MM722)
172
Maintenance of the Avaya G350 Media Gateway
June 2004
Notes:
•
Error Type 1 – The circuit pack stopped functioning or is physically removed from the system.
This alarm logs approximately 11 minutes after removing the circuit pack and/or the SAKI Sanity
Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot as the error indicates.
See note (g).
•
Error Type 257 – Transient communication problems between the switch and this circuit pack.
Execute the
test board GGGVM
command and refer to the repair procedures for the Control
Channel Loop Around Test (#52).
•
Error Type 513 – On-board hardware failure. Aux data values correspond to the following
detected errors:
Reset the circuit pack with the
busyout board GGGVM
and
reset board GGGVM
commands. When reset, the circuit pack executes a set of tests to detect the presence of any of the
faults listed above. Detection of one of these errors during initialization causes the circuit pack to
lock-up and appear insane to the system. See the repair procedure in Note (
•
Error Type 769 – The circuit pack detects a program logic error. While no action is required, this
error can lead to other errors against this circuit pack.
1025 (
NPE/NCE Audit Test
(#50)
None
ON
1291 (
4359
Clear Error Counters
(#270)
MINOR
ON
3586 (
MINOR
OFF
3840(
h)
4096
to
4101
3842 (
46095
3843 (
j)
46097
* Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description
and follow the recommended procedures.
Table 102: Error Log Entries and Test to Clear Values 2 of 2
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2
Aux Value
Detected Error
4352
External RAM error
4353
Internal RAM error
4355
ROM Checksum error
4357
Instruction set error
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...