Avaya Communication Manager controlled maintenance
XXX-BD (Common Port Media Module)
234
Maintenance of the Avaya G350 Media Gateway
June 2004
Notes:
•
Error type 1 indicates the Media Module has stopped functioning or has been physically removed
from the system. The alarm is logged approximately 11 minutes after removal of the Media
Module or failure of the SAKI Sanity Test (#53).
Check for the physical presence of the Media Module in the slot indicated by the alarm. If the
Media Module is not present, insert one of the proper type. If the Media Module is present and its
red LED is lit.
•
This error indicates the Media Module has been busied out. Release the Media Module via
release board GGGVS
.
•
The Media Module has been logically administered but not physically installed. The alarm should
clear when the circuit pact is installed.
If the Media Module is already installed:
1
Run
test board GGGVS long
and look at any test failures or error codes generated.
2
If the test does not clear error 23, then execute
reset board GGGVS
and run the long
test again.
3
If the reset/test does not clear error 23, replace the Media Module.
23(c)
0
None
WARNING
OFF
125 (e)
None
MINOR
ON
257
65535
Control Channel
Test (#52)
MINOR
ON
test board GGGVS sh
r 20
257 (g)
Any
None
267
0
None
WARNING
ON
513 (h)
Any
None
MINOR
ON
test board GGGVS sh
769 (i)
4358
None
1281 (k)
Ringing Application
Test (#51)
MINOR
ON
test board GGGVS r 2
1538 (l)
Any
None
WARNING
/ MINOR
ON
3840 (n)
Any
None
3999 (o)
Any
None
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 132: Common Port Media Module Maintenance Error Log Entries 2 of 2
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...