Notes:
•
(a) Error Type 1
- these in-line errors can only be resolved over time:
— Aux Data 40960 indicates that too many simultaneous incoming ringing attempts were
made on this board. Only 4 ports on a board may ring simultaneously. A 5th incoming call
will cause an inline error from the board.
— Aux Data 40975 indicates that the terminal equipment was on-hook when ring-tip was
detected during ringing. This usually indicates a failure in the terminal equipment or the
type of terminal has a low ringer impedance.
•
Call the terminal equipment and verify that the terminal rings.
•
If the terminal does not ring, then replace it.
•
Otherwise, use the
test port GGGVSpp
command, and follow the procedure for
Test #48.
— 40977 indicates that no terminal equipment was connected when ringing was attempted.
•
Run the short test via the
test port GGGVSpp
command, and follow the
procedure for the results of Test #48.
•
(b) Error Type 15
- a software audit error that does not indicate any hardware malfunction
— Run the Short Test Sequence and investigate any associated errors.
•
(c) Error Type 130
- indicates that the Media Module has been removed or has been insane for
more than 11 minutes
— To clear the error, reseat or replace the Media Module.
•
(d) Error Type 257
- an in-line error that can only be resolved over time. This error indicates
that ringing voltage is absent
— If not resolved over time, replace the module.
•
(e) Error Type 513
- Test #48 can cause some terminal equipment to ring briefly during daily
maintenance.
— If this disturbs the customer or the terminal equipment, disable it by setting the
Tests
field on the
change station
extension
form to
n
. This may also disable Test #35.
769
Battery Feed
Test (#35)
MIN/
WRN**
ON
test port GGGVSpp sh r 2
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
**Minor alarms on this MO may be downgraded to Warning alarms based on the values used in
the
set options
command.
Table 35: Analog Line Error Log Entries 2 of 2
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...