Media Server alarms
S8300 alarms – _WD
312
Maintenance of the Avaya G350 Media Gateway
June 2004
Table 165: Alarm #10
Number
10
Source
_WD
Event ID
7
Alarm Level
Major
Alarm Text Description
Cannot open exe using config file PID
Possible Causes
Watchdog has a bad path name for an application it is supposed to
start.
Determining Cause
Go to the Web Interface; choose Diagnostics; View System Logs;
select Watchdog Logs
Resolution
1. Verify that the file named in the log exists and is executable.
2. Verify that the string in watchd.conf is correct.
3. From the Web Interface, choose Alarms and Notification; select
the appropriate alarm; choose Clear
Table 166: Alarm #11
Number
11
Source
_WD
Event ID
15
Alarm Level
Major
Alarm Text Description
Detected a rolling reboot
Possible Causes
Watchdog has detected x number of Linux reboots within y
minutes, where x and y are configurable in
/etc/opt/ecs/watchd.conf. A variety of bad things could have
happened to cause a rolling reboot, it’s not possible to list them all.
Determining Cause
Go to the Web Interface; choose Diagnostics; View System Logs;
select Watchdog Logs
Resolution
1. (Lab only) Make sure all the executables listed in the
watchd.conf exist and are executable. It has been found that the
most common cause for rolling reboot is that files are not where
they are expected
2. If everything looks OK with step 1, further investigation of trace
log is necessary.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...