Avaya Communication Manager controlled maintenance
DIG-LINE (Digital Line)
124
Maintenance of the Avaya G350 Media Gateway
June 2004
•
Internal system error. No action is necessary.
•
There is a problem with the voice terminal EEPROM. When the voice terminal is repaired the
alarm will be resolved with the passing of time.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing error codes associated with
the Voice and Control Channel Local Looparound Test, for example, you may also clear errors generated
from other tests in the testing sequence.
Table 65: Order of Investigation
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND*
Digital Terminal Remote Looparound Test (#1201)
Note
:
This Test ABORTS
X
D
Voice and Control Channel Local Looparound Test
(#13)
Note
:
This Test ABORTS
X
ND
Digital Line NPE Crosstalk Test (#9)
Note
:
This Test ABORTS
X
ND
Digital Line Electronic Power Feed Test (#11)
X
ND
DIG-LINE Station Lamp Updates Test (#16)
X
X
ND
Station (Digital) Audits Test (#17)
X
X
ND
*D = Destructive; ND = Nondestructive
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...